Fer FERtech F 32 D Instructions For Use, Installation And Maintenance page 20

Table of Contents

Advertisement

Available languages

Available languages

5.5 Wiring diagram
1kW
LC32
95
1
2
3
Important: Before connecting the room thermostat or the remote timer
A
trol, remove the jumper on the terminal block.
20
EN
81
114
38
138
72
139
fig. 22 - Electrical circuit
cod. 354
FERtech F 24 D - F 32 D
ABM01
T
T
T
°
°
°
42
278
44
1
2
3
4
581 - Rev. 03 -
/2015
L
L
N
N
L
N
32
230V
16
50 Hz