Sharp AU-MP14 Service Manual page 3

Split system indoor/outdoor unit
Table of Contents

Advertisement

2. AH-MP14 / AU-MP14
ITEMS
Cooling capacity
Moisture removal
Electrical data
Phase
Rated frequency
Rated voltage
Rated current
Rated input *
Power factor
Compressor
Type
Model
Oil charge
Refrigerant system
Evaporator
Condenser
Control
Refrigerant volume 960g
Noise level
High
Mid.
Low
Fan system
Drive
Air flow quantity
High
Mid.
Low
Fan
Connections
Refrigerant coupling
Refrigerant tube size Gas, Liquid
Drain piping
Others
Safety device
Air filters
Net dimensions
Width
Height
Depth
Net weight
INDOOR UNIT
AH-MP14
kW
3.50
Liters/h
Single
Hz
50
V
220
A
5.1
W
1090
%
97 - 99
Hermetically sealed rotary type
RH207VXGT
520cc (DIAMOND MS56)
Slit fin and Grooved tube type
Slit fin and Grooved tube type
Capillary tube
dB(A)
39
dB(A)
33
dB(A)
29
Direct drive
m3/min.
10.2
m3/min.
9.6
m3/min.
8.7
Cross flow fan
Flare type
φ
3/8" , 1/4"
φ φ
mm
O.D 18
Compressor : Internal protector
Fan motor : Thermal fuse / Protector
Fuse, Micro computer control
Polypropylene net (Washable)
mm
790
mm
278
mm
198
kg
10
3
OUTDOOR UNIT
AU-MP14
48
27
Propeller fan
730
540
250
34

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ah-mp14Au-129Ah-129