DISASSEMBLING PROCEDURE

[1] INDOOR UNIT
Be sure to disconnect the power supply cord from the AC power outlet before starting the disassembly procedure. When reassembling the unit-
after repairing, besure to install screws to their original positions.
The screws used are not the same in specifications such as corrosion-resistant treatment, tip shape and length.
After the air conditioner is repaired or parts or replaced, measure insulation resistance of the equipment using and insulation resistance meter.
if the measured resistance is lower than 1M , inspect parts and repair or replace defective parts.
1) Open the open panel.
2) Remove screw fixing the cord clamp.
3) Remove the cord clamp.
4) Remove the unit-to-unit wiring from the terminal board(4).
17
MODEL: AH-129 ,AH-MP14
5) Pushing the 2 hooks, disconnect the louver base(2)
6) Remove 2 air filters.
7) Remove the Screw cover (use the(-)driver).
8) Remove the cover.