Model
CS-F43DTE5
Cooling capacity
12.5kW
Ambient
Temperature Air Entering Condenser (°C D.B.)
Return
25°C
Air
TC
D.B.
W.B.
kW
17
13.01
23
19
13.74
22
15.01
17
12.86
25
19
13.76
22
15.00
17
12.70
27
19
13.78
22
14.99
17
12.67
29
19
13.75
22
14.93
17
12.66
32
19
13.73
22
14.89
TC: Cooling Capacity
Cooling capacities are based on conditions
3 phase, 50Hz 400V
Indoor temp. 27°C D.B. 19°C W.B.
Outdoor temp. 35°C D.B.
Standard air volume 31 m
30°C
35°C
40°C
TC
TC
TC
kW
kW
kW
12.50
11.76
10.88
13.31
12.63
11.78
14.60
13.93
13.04
12.36
11.64
10.80
13.28
12.57
11.70
14.54
13.83
12.88
12.22
11.53
10.72
13.25
12.50
11.63
14.48
13.73
12.75
12.22
11.50
10.80
13.25
12.50
11.72
14.42
13.64
12.77
12.22
10.69
10.86
13.25
12.51
11.78
14.38
13.62
12.78
3
/min
Ambient
43°C
Return
TC
Air
kW
D.B.
W.B.
10.24
17
11.18
23
19
12.42
22
10.19
17
11.09
25
19
12.30
22
10.14
17
11.00
27
19
12.19
22
10.27
17
11.14
29
19
12.18
22
10.35
17
11.23
32
19
12.18
22
IPT: Cooling Power Consumption
113
Temperature Air Entering Condenser (°C D.B.)
25°C
30°C
35°C
IPT
IPT
IPT
kW
kW
kW
3.89
4.22
4.59
4.13
4.47
4.87
4.46
4.83
5.26
3.90
4.21
4.58
4.15
4.48
4.88
4.48
4.84
5.27
3.90
4.20
4.58
4.17
4.49
4.89
4.50
4.85
5.28
3.88
4.20
4.52
4.14
4.48
4.83
4.57
4.94
5.32
3.86
4.19
4.49
4.13
4.48
4.79
4.61
5.00
5.35
40°C
43°C
IPT
IPT
kW
kW
5.04
5.34
5.34
5.66
5.77
6.11
5.01
5.31
5.33
5.65
5.75
6.10
4.97
5.27
5.32
5.63
5.74
6.08
4.86
5.06
5.19
5.41
5.71
5.95
4.78
4.92
5.10
5.26
5.70
6.02