Checks Flowchart - Rheem RA1460AJ1NA Installation Instructions Manual

Air cooled condensing units ra14 model series – 14 seer
Hide thumbs Also See for RA1460AJ1NA:
Table of Contents

Advertisement

DIAGNOSTICS
Electrical Checks Flowchart
30
YES
Repair and
Recheck
YES
Repair and
Recheck
YES
Run Capacitor
Start Capacitor
Potential Relay
Compressor Internal
Overload Open
Compressor Winding
Unit Wiring and
Connections
Open
Unit Wiring and
Connections
Unit
Running?
NO
Thermostat
Problem?
NO
Transformer
Problem?
NO
Voltage on Compressor
Side of Contactor?
NO
Circuit Breakers or
Fuses Open
YES
Compressor Winding
Grounded
Outdoor Fan Motor
Grounded
Grounded Capacitor
Replace Fuses or Reset
Breakers and Recheck
System
YES
Go to Mechanical Checks
for Cooling or Heating
NO
Voltage on Line
Side of Contactor?
YES
Compressor
NO
Contactor
Hi Pressure Cut-Out
Hot Gas Sensor
Compressor
Time-Delay
Unit Wiring and
Connections