Checks:
 Check the correct function of all safety contact pads. These are located on the
bottom and top trolley, on the side and below the drive unit and under the footrest.
These contact pads should top the lift when pressed against the driving direction.
See below:
 Check the function of the seat rotation switch and the armrest switch.
 Check the function of the curve speed reduction switch/lever.
 Check the function of the landing stations speed reduction pin/switch.
 Check the function of the intermediate landing pin/switch.
 Check the function of the final stop pin/switch.
 Check the function of the landing limit switch. This is the contact switch in the safety
pads of the lower trolley. Check the correct position of the stop pin that activates the
safety pads in the landing assembly.
 Check the correct charging of the drive unit in the landings stations.