Siemens TRANSMAG 2 Operating Instructions Manual page 3

Electromagnetic with pulsed alternating field

Advertisement

Flow Measurement
SITRANS F M
Transmitter TRANSMAG 2 with sensor 911/E
Medium conditions
• Process temperature
Minimum conductivity of medium
• With SITRANS F M 911/E sensors
Design
Weight of transmitter
Remote version
Maximum cable length
Housing
Displays and keypad
General display
Multi-display for
Keypad
Power supply
corresponding to rating plate
• AC supply
• Power consumption
Line fuse
Magnet current fuse
Sensor cables between sensor and transmitter
The signal voltage proportional to the flow and present at the
electrodes of the EMF is only a few µV to mV. Superimposed on
this are electrochemical interferences resulting from the contact
between the electrodes and liquid, and which can be up to sev-
eral Volt. Also frequently superimposed are line frequency inter-
ferences, interferences resulting from vibrations on the pipelines
or signal cables, as well as strong magnetic fields in the vicinity.
Sufficient shielding must therefore be provided, as well as fixed
routing of the signal cables (electrode and magnet current ca-
ble) in the case of remote versions. This also applies to devices
with integral preamplifier (smartPLUG). The cable length be-
tween the sensor and transmitter must not exceed 100 m
(328 ft).
Attention must also be paid to the cable routing. Signal cables
must be routed free of vibration, and protected against strong
magnetic and stray fields. In case of doubt, the sensor cables
must be routed in earthed steel conduit.
icenta Controls Ltd
Tel: +44 (0)1722 41
3/106
Siemens FI 01 · 2014
© Siemens AG 2013
-20 ... +150 °C (-4 ... 302 °F)
depending on the liner
 1 µS/cm (0.1 µS/cm depending
on medium)
4.4 kg (9.7 lb)
Transmitter must be connected to
sensor using shielded cable
100 m (328 ft)
Die-cast aluminum, painted
LCD, backlid, two lines with
16 characters each
Flow, totalizer, flow velocity
4 keys for entering parameters
100 ... 250 V AC  15 %,
47 ... 63 Hz
Approx. 120 ... 630 VA, depend-
ing on sensor
100 ... 230 V AC: T1.6A
F5A/250 V
Fax: +44 (0)1722
Selection and Ordering data
SITRANS F M electromagnetic
transmitter TRANSMAG 2
for alternating field, remote version,
110 ... 230 V AC
Output/communication
4 ... 20 mA with HART protocol
PROFIBUS PA connection
4 ... 20 mA with HART protocol,
digital input
Operator display and keypad
Without
With
Cable glands
M20/M16 x 1.5
½" NPT
Selection and Ordering data
Additional information
Please add "-Z" to Article No. and specify Order
code(s) and plain text.
Strengthened mounting bracket for wall and pipeline
installation
Measuring range, specify in plain text:
3
Y01: 0 to ... m
/h
Pulse significance, specify in plain text:
Y02: 0 to ... pulses/l
Setting of digital outputs, specify in plain text:
Y03: Setting of digital outputs: ...
Measuring-point number (max. 8 characters), specify in
plain text: Y15: ..........
Measuring-point description (max. 16 characters),
specify in plain text: Y16: ..........
Stainless steel tag plate
Other post-production requirements (add plain text)
Operating instructions for SITRANS F M TRANSMAG 2
Description
Article No.
A5E00102775
• English
A5E00192774
• German
A5E00135276
• Spanish
A5E00135275
• French
This device is shipped with a Quick Start guide and a CD containing fur-
ther SITRANS F literature.
All literature is also available for free at:
http://www.siemens.com/flowdocumentation
e: sales@icenta.co.uk
Article No.
7
7
7
7 M E 5 0 3 4 -
A A
1 -
A A 0
0
1
2
0
1
1
2
Order code
A02
Y01
Y02
Y03
Y15
Y16
Y17
Y99
www.icenta.co.uk