Location
This heater is intended for use in a fireplace opening generally conforming to British Standard 1251 for a nominal 400mm (16
inch) or 450mm (18 inch) Fireplace. It may also be located in other fireplace openings or in a wooden surround, where the
following dimensions are available.
Width
390 – 450mm
Height
555 – 590mm
Depth
At least 75mm
Installing
The heater must be fixed into position to prevent it from being tipped over.
The following fixing options are available. The parts required for both fixing options are included with all appliances.
Screw fixing
Wire fixing
The heater must not be located under a fixed electrical socket, the socket must always be accessible in order to disconnect the
heater from the electrical supply for maintenance or when replacing a lamp.
Important! This appliance must be earthed.
Important! This appliance must be earthed.
Important! This appliance must be earthed.
Important! This appliance must be earthed.
This heater is supplied with a 3 pin 13A fused rewireable plug with a 1mm
If the plug is not suitable for your socket, remove the plug and fit an appropriate plug. If in doubt, consult a qualified
electrician.
The wires in the mains lead are coloured in accordance with the following code:-
Green & Yellow = Earth
Blue = Neutral
Brown = Live
As the colours of the wires in the mains lead may not correspond with the coloured markings identifying the terminals in your
plug, fit the wires as follows:-
The wire which is coloured Green & Yellow must be connected to the terminal in the plug which is marked with the letter E
or by the earth symbol
The wire which is coloured Blue must be connected to the terminal which is marked with the
letter N or coloured Black.
The wire which is coloured Brown must be connected to the terminal which is marked with the letter L or coloured Red.
If the mains cable is damaged then, for your safety, it must be replaced with an approved cable your authorised service agent
or a qualified electrician.
The mains supply cable must be safely routed from the heater to an electrical socket. Provision is made for left/right or rear
cable entry. Using one of the three cable guides at the base of the heater. To relocate, open the appropriate latch on the cable
guide and refit the mains cable into the required position.
The heater body should be fixed in position before the front surround is finally fitted.
Please study the illustrations carefully to avoid damage to the heater.

Front Removal

Carefully remove the front surround by removing the two trim fixing screws and lifting upwards and forward – See figure 1
Keep the front surround and screws in a safe place when installing the fire.
Offer the heater body to the fireplace opening to ensure that it will fit before continuing with the

installation.

Figure 1
or coloured Green or Green & Yellow.
INSTALLATION
2
3core mains flex.
3 3 3 3