1-3. SPECIFICATIONS

Model
Indoor unit
Outdoor unit
MSZ-SF15VA
MSZ-SF20VA
*1 Connect to the power switch which has a gap of 3 mm
or more when open to interrupt the source power phase.
(When the power switch is shut off, it must interrupt all
phases.)
*2 Use wires in conformity with design 60245 IEC 57.
*3 Never use pipes with thickness less than specified. The
pressure resistance will be insufficient.

1-4. INSTALLATION DIAGRAM

ACCESSORIES
Check the following parts before installation.
<Indoor unit>
(1) Installation plate
(2) Installation plate fixing screw 4 × 25 mm
(3) Wireless remote controller
(4) Felt tape (For left or left-rear piping)
(5) Remote controller holder
(6) Fixing screw for (5) 3.5 × 16 mm (Black)
(7) Battery (AAA) for (3)
* Note:
Place indoor/outdoor unit connecting wire (A) at least 1 m
away from the TV antenna wire.
Units should be installed by licensed contractor according
to local code requirements.
Power supply *1
Rated Voltage
Frequency Breaker capacity
230 V
50 Hz
*7
*4 Use a copper pipe or a copper-alloy seamless pipe.
*5 Be careful not to crush or bend the pipe during pipe
bending.
*6 Refrigerant pipe bending radius must be 100 mm or
more.
*7 Refer to the installation manual of the multi-type outdoor
units.
1
5
1
1
1
2
2
Be sure to use wall hole
sleeve (C) to prevent
indoor/outdoor connecting
wire (A) from contacting
metal parts in the wall
and to prevent damage
by rodents in case the
wall is hollow.
After the leak test, ap-
ply insulating material
tightly so that there is
no gap.
When the piping is to be attached to a wall containing metals (tin
plated) or metal netting, use a chemically treated wooden piece 20 mm
or thicker between the wall and the piping or wrap 7 to 8 turns of insula-
tion vinyl tape around the piping.
To use existing piping, perform COOL operation for 30 minutes and
pump down before removing the old air conditioner. Remake flare ac-
cording to the dimension for new refrigerant.
Before installation
This installation manual is only for the indoor unit installation. In install-
ing the outdoor units, refer to the installation manual attached to each
outdoor unit. Any structural alternations necessary for the installation
must comply with the local building code requirements.
Wire specifications *2
Power supply
*7
*7
*8 Insulation material : Heat resisting foam plastic 0.045
specific gravity
*9 Be sure to use the insulation of specified thickness.
Excessive thickness may cause incorrect installation
of the indoor unit and insufficient thickness may cause
dew drippage.
PARTS TO BE PROVIDED AT YOUR SITE
(A) Indoor/outdoor unit connecting wire*
(B) Extension pipe
(C) Wall hole sleeve
(D) Wall hole cover
(E) Pipe fixing band
(F) Fixing screw for (E) 4 × 20 mm
(G) Piping tape
(H) Putty
Drain hose
(I)
(or soft PVC hose, 15 mm inner diameter or hard PVC pipe
VP16)
(J) Refrigeration oil
Indoor unit
Wall hole
sleeve (C)
Cut off the
extra length.
Drain piping for outdoor unit
Install the unit horizontally.
Do not use drain socket in cold regions. Drain may freeze and
make the fan stop.
The outdoor unit produces condensate during the heating opera-
tion. Select the installation place to ensure to prevent the outdoor
unit and/or the grounds from being wet by drain water or damaged
by frozen drain water.
Pipe size
(thickness *3, *4)
Indoor/outdoor connecting wire
Gas / Liquid
4-core
ø9.52 / 6.35 mm
1.0 mm
(0.8 mm)
2
Wall hole cover (D)
Seal the wall hole
gap with putty (H).
Fix the pipe to wall
with pipe fixing
band (E).
Pipe fixing band
(E)
Fixing screw
(F)
1
1
1
1
2 to 5
2 to 5
1
1
1 or 2
1
En-2

Advertisement

Table of Contents
loading

This manual is also suitable for:

Msz-sf20va