Module Application Class-Class A; General Installation - GH Solar GHxxxP-36 Series Installation Manual

Solar pv system
Table of Contents

Advertisement

produce more current and/or voltage than reported at standard test conditions. The
suggested fuse must be used for over-current protection.
Accordingly, the values of Isc and Voc marked on this module should be multiplied by a
factor of 1.25 when determining component voltage ratings, conductor capacity, fuse sizes
and size of controls connected to the PV output. Modules have passed mechanical load
test 5400Pa according to the IEC61215. To avoid exceeding the maximum load,
site-specific live loads such as wind and snow would be taken into account. Installation
shall be in accordance with local standard and conditions. Climate conditions Ambient
temperature: -20~+40℃
36pcs: The maximum number of series connection: 35;
The maximum number of parallel connection: 2;
48pcs: The maximum number of series connection: 27;
The maximum number of parallel connection: 2;
54pcs: The maximum number of series connection: 23;
The maximum number of parallel connection: 2;
60pcs: The maximum number of series connection: 21;
The maximum number of parallel connection: 2;
72pcs: The maximum number of series connection: 17;
The maximum number of parallel connection: 2;
1.4.Module Application Class-Class A:
General access, hazardous voltage, hazardous power applications Modules rated for use
in this application class may be used in systems operating at greater than 50VDC or 240W,
where general contact access is anticipated. Modules qualified for safety through
IEC61730-1 and this part of IEC61730 within this application class are considered to meet
the requirement for safety class Ⅱ.
Whenever necessary to comply with local codes, use a listed fuse or circuit breaker, rated
for the maximum series fuse rating of the module and the system voltage.
2. General Installation:
Installing solar Photovoltaic systems may require specialized skills and knowledge.
Installation should be performed only by qualified persons. Each module comes with a
permanently attached junction box. Box can provide customers with fitted cables for ease
of installation if desired.
Installers should assume the risk of all injury that might occur during installation, including,
without limitation, the risk of electric shock. Do not disconnect under load. Photovoltaic
solar modules change light energy to direct-current electrical energy. Modules may be
ground mounted, mounted on rooftops, vehicles or boats.
Proper design of support structures is responsibility of the system designers and
installers.
Do not attempt to disassemble the modules, and do not remove any attached nameplates
or components from the modules. Do not apply paint or adhesive to module top surface.