  • Page 1 INSTALLATION MANUAL FOR SOLAR PV SYSTEM GH SOLAR SOLAR MODULES...
  • Page 2: Table Of Contents

    Photovoltaic Module User Manual 1. General information........................3 1.1. Overview..........................3 1.2. Warning..........................3 1.3. Safety Precautions:......................3 1.4. Module Application Class-Class A:................4 2. General Installation:........................4 3. Mechanical Installation......................5 3.1. Mechanical Installation introduction................5 3.1.1. Screw fitting......................6 3.1.2. Independent installation of Z-type clamp single module......7 3.2.
  • Page 3: General Information

    1. General information 1.1.Overview This guide contains information regarding the installation and safe handling of Ganghang. Photovoltaic module (hereafter is referred to as “module”). Installers must read and understand the guide before installation. Any questions, please contact our sales department for further explanations. 1.2.Warning The installer should conform to all safety precautions in the guide and local codes when installing a module.
  • Page 4: Module Application Class-Class A

    produce more current and/or voltage than reported at standard test conditions. The suggested fuse must be used for over-current protection. Accordingly, the values of Isc and Voc marked on this module should be multiplied by a factor of 1.25 when determining component voltage ratings, conductor capacity, fuse sizes and size of controls connected to the PV output.
  • Page 5: Mechanical Installation

    When installers installing the system, abide with all local, regional and national statutory regulations. Obtain a building permit where necessary. 3. Mechanical Installation 3.1.Mechanical Installation introduction The PV modules should be mounted in a location where they will receive maximum sunlight throughout the year.
  • Page 6: Screw Fitting

    3.1.1. Screw fitting The modules shall be secured with M8 stainless steel or equivalent bolts with washers and nuts. The applied torque is about 8 Newton-meters. The module frame must be attached to a mounting rail using M8 corrosion-proof screws together with spring washers and flat washers in four symmetrical locations on the PV module.
  • Page 7: Independent Installation Of Z-Type Clamp Single Module

    Note:  Clearance between modules frames and surface of the wall or roof is required to prevent wiring damage and to allow air to circulate behind the module. Recommended stand-off height is 115mm.  When mounting, be sure that the module’s drain holes are not blocked. ...
  • Page 8 transverse bar. The 5400 Pa test takes the inside installation hole position as benchmark, and fix clamp transverse bar. The detailed installation method shall be seen in the following sketch: Figure1 above: PV module installed at long side with Clamp fitting method Table 1 above: Mechanical dimensions when modules installed at long side with Clamp fitting method...
  • Page 9 Figure 2 above: PV module installed at short side with Clamp fitting method Table 2 above: Mechanical dimensions when modules installed at short side with Clamp fitting method...
  • Page 10: Site Selection

    3.2.Site selection 3.2.1. Ground mounting: Select the height of the mounting system to prevent the lowest edge of the module from being covered by snow for a long time in winter in areas that experience heavy snowfalls. In addition, assure the lowest portion of the module is placed high enough so that it is not shaded by plants or trees or damaged by sand and stone driven by wind.
  • Page 11: Electrical Installation

    4. Electrical Installation 4.1.Grid-connected electrical system: The DC electrical energy generated by photovoltaic systems may also be converted to AC and connected to a utility grid system. As local utilities’ policies on connecting renewable energy systems to their grids vary from region to region. Consult a qualified system designer or integrator to design such a system.
  • Page 12: Grounding

    5. Grounding All module frames must be attached to solid ground. A qualified electrician must complete ground connections. The grounding wire must be properly fastened to the module frame to assure good electrical contact. Use the recommended type, or an equivalent, connector for this wire.
  • Page 13: Modules' Electrical Parameter As Below

    Assembly Type Material Number Screw Ф4mm Stainless steel Stainless steel Ф4mm Washer Stainless steel Ф4mm Claw Washer Ф4mm Stainless steel Cupule Washer Ф4mm Stainless steel Bypass diode type Used in junction box type Ф4mm PST4020 GF20 Ф4mm Junction box type: GF20, connector type: 05-6, from Renhe Photovoltaic Technology Co.,Ltd 6.
  • Page 14: Ghxxxp-48 (190-220W)

    Tolerance of ±3 ±3 ±3 ±3 ±3 Rating [%] : Rated Short Circuit 8.48 8.77 9.05 9.34 Current [A] : Rated Open Circuit 22.47 22.49 22.51 22.53 22.54 Voltage [V] : Over-current protection rating [A]: Application Class Class A Class A Class A Class A Class A...
  • Page 15: Ghxxxp-54 (210-250W)

    6.3.GHxxxP-54 (210-250W) Type Name or GH210P-5 GH215P-5 GH220P-5 GH225P-5 GH230P-5 Model No. : Maximum System Voltage 1000 1000 1000 1000 1000 [VDC] : Maximum Power 28.02 28.03 28.04 28.05 28.08 Voltage(Vmp) Maximum Power 7.49 7.67 7.85 8.02 8.19 Current (Imp) Rated Maximum Power [W] Tolerance of...
  • Page 16: Ghxxxp-60 (230-275W)

    Rated Maximum Power [W] Tolerance of Rating ±3 ±3 ±3 ±3 [%] : Rated Short Circuit 9.24 9.43 9.52 9.58 Current [A] : Rated Open Circuit 33.48 33.49 33.51 33.52 Voltage [V] : Over-current protection rating [A]: Application Class (IEC Class A Class A Class A...
  • Page 17: Ghxxxp-72 (275-315W)

    Application Class (IEC Class A Class A Class A Class A Class A 61730) : Protection Class II Class II Class II Class II Class II Class : Dimensions (l x 1640*992* 1640*992* 1640*992* 1640*992* 1640*992* w x h) [mm] : Module area 1.63 1.63...
  • Page 18 Maximum System Voltage 1000 1000 1000 1000 1000 [VDC] : Maximum Power 37.38 37.39 37.42 37.45 37.51 Voltage(Vmp) Maximum Power Current 7.36 7.49 7.62 7.74 7.86 (Imp) Rated Maximum Power [W] Tolerance of ±3 ±3 ±3 ±3 ±3 Rating [%] : Rated Short Circuit Current 8.13...
  • Page 19: Ghxxxm-36 (140-165W)

    44.69 44.71 44.73 Class A Class A Class A Class II Class II Class II 1957*992* 1957*992* 1957*992* 1.94 1.94 1.94 6.6.GHxxxM-36 (140-165W) Type Name GH140M-3 GH145M- GH150M- GH155M- GH160M- GH165M- or Model No. : Maximum System 1000 1000 1000 1000 1000 1000...
  • Page 20: Ghxxxm-48 (195-220W)

    Protection Class II Class II Class II Class II Class II Class II Class : Dimensions (l 1480*670* 1480*670 1480*670 1480*670 1480*670 1480*670* x w x h) [mm] : Module area 0.99 0.99 0.99 0.99 0.99 0.99 [m²] : 6.7.GHxxxM-48 (195-220W) Type Name or GH195M- GH200M-...
  • Page 21: Ghxxxm-54 (215-250W)

    w x h) [mm] : Module area 1.31 1.31 1.31 1.31 1.31 1.31 [m²] : 6.8.GHxxxM-54 (215-250W) Type Name or GH215M-5 GH220M-5 GH225M-5 GH230M-5 Model No. : Maximum System 1000 1000 1000 1000 Voltage [VDC] : Maximum Power 27.69V 27.76V 27.83V 27.91V Voltage(Vmp)
  • Page 22: Ghxxxm-60 (235-275W)

    Maximum System 1000 1000 1000 1000 Voltage [VDC] : Maximum Power 27.99V 28.05V 28.12V 28.2V Voltage(Vmp) Maximum Power 8.39A 8.56A 8.71A 8.87A Current (Imp) Rated Maximum Power [W] Tolerance of Rating ±3 ±3 ±3 ±3 [%] : Rated Short Circuit 9.19A 9.39A 9.57A...
  • Page 23 Circuit Voltage [V] : Over-current protection rating [A]: Application Class Class A Class A Class A Class A (IEC 61730) : Protection Class : Class II Class II Class II Class II Dimensions (l x w 1640*992* 1640*992* 1640*992* 1640*992* x h) [mm] : Module area [m²] : 1.63...
  • Page 24: Ghxxxm-72 (280-330W)

    6.10. GHxxxM-72 (280-330W) Type Name or GH280M-7 GH285M-7 GH290M-7 GH295M-7 Model No. : Maximum System Voltage 1000 1000 1000 1000 [VDC] : Maximum Power 36.37V 36.47V 36.58V 36.69V Voltage(Vmp) Maximum Power Current 7.7A 7.81A 7.93A 8.04A (Imp) Rated Maximum Power [W] Tolerance of ±3 ±3...
  • Page 25 Maximum Power 36.8V 36.91V 37.01V 37.12V 37.21V 37.32V Voltage(Vmp) Maximum Power Current 8.15A 8.26A 8.38A 8.49A 8.6A 8.71A (Imp) Rated Maximum Power [W] Tolerance of ±3 ±3 ±3 ±3 ±3 ±3 Rating [%] : Rated Short Circuit Current 8.63A 8.79A 8.91A 9.04A 9.17A...
  • Page 26: Maintenance

    Rated Open Circuit Voltage 46.1V [V] : Over-current protection rating [A]: Application Class (IEC Class A 61730) : Protection Class : Class II 1957*992* Dimensions (l x w x h) [mm] : Module area [m²] : 1.94 If the support frame is made of metal, the surface of the frame must be electroplated and have excellent conductivity.
  • Page 27: Contact Us

    accept responsibility and expressly disclaims liability for loss, damage, or expense arising out of or in any way connected with such installation, operation, use or maintenance. No responsibility is assumed by GH for any infringement of patents or other rights of third parties, which may result from use of the PV product.

Table of Contents