General Information; Overall Dimensions; Location Level And Plumb; Installation Hints - Bosch HEI8054C Installation Instructions Manual

Electric and induction ranges
Table of Contents

Advertisement

Available languages

Available languages

General Information

Overall Dimensions

Dimension
Inches
Height
36½" - 38"
Width
31½"
Depth
26¾"

Location Level and Plumb

For best results, cabinets, countertops, walls and floors in
the installation location should be as level and plumb as
possible. Variance may cause damage to countertops and
floors during installation, and may adversely affect cooking
and baking performance.

Installation Hints

To make the range lighter and easier to handle during
installation, remove the range oven door and warming
drawer (see "Removing the Oven Door" on page 13).
If the warming drawer is not removed,then tape must be
placed securely on the warming drawer before installation
to prevent it from opening while the range is being installed.
Place a piece of cardboard or cloth under the range during
installation to protect floors.

Electrical Requirements

Refer to data plate for more information. See the product
"Data Plate" in the section on Service in this manual.
We recommend that the range be installed with a
power cord set (not supplied with U.S. models). The
electrical rating of the power cord set must be 120/240 volt,
40 amperes minimum. The power cord set must be marked
"For Use with Ranges." Always use a new power cord.
Verify that wiring to the house is adequate. Contact your
local utility company to verify that the present electric
service to your home is adequate. In some instances, the
size of the wiring to the house and service switch must be
increased to handle the electrical load demanded by the
range.
Some wiring codes require a separate circuit with separate
disconnect switch and fuses either in the main entrance
panel or in a separate switch and fuse box.
The range requires a minimum of a three-wire 120/240 or
120/208 volt, 40 - 50 amp, 60 Hz AC circuit. Check local
codes for proper amperage ratings. A four-wire connection
is preferred. Most local building regulations and codes
require that electrical wiring be done by licensed
electricians. Be sure to install your range according to the
English 4
Centimeters
92.7 cm - 96.6 cm
80 cm
68.1 cm
electric codes in your region.
Electrical kW Rating
Ranges are dual rated for use on either 120/240 VAC or
120/208 VAC. Check the data plate for the kW rating.
Reference the kW rating in the table below to determine
amperage requirements.
VOLTS
HZ
RATING
A/C
KW
120/240
60
13.0
120/240
60
13.8
120/208
60
120/208
60
10.4
* Varies by location. Check local codes.
Electric Outlet Location
A flush mount 208/240 VAC dedicated circuit outlet is
required. Use the diagram below to make sure your
installation in properly prepared for the range. Note the
available space for the electrical outlet is shown in box (E)
in the illustration following.
CIRCUIT
BREAKER
40 or 50 amps*
40 or 50 amps*
9.8
40 or 50 amps*
40 or 50 amps*
9001126425 Rev A

Advertisement

Table of Contents
loading

This manual is also suitable for:

Heip054cHeip054uHiip054cHiip054uHei8054u

Table of Contents