Sanyo PLC-XU75A Service Manual page 43

Hide thumbs Also See for PLC-XU75A:
Table of Contents

Advertisement

Electrical Adjustments
Group/
IteM NAMe
Item
Group
Auto calibration (Ycbcr)
264
0 Y-OFFSET AREA H START
1 Y-OFFSET AREA V START
 CB - OFFSET AREA H
START
3 CB - OFFSET AREA V START
CR - OFFSET AREA H
4
START
5 CR - OFFSET AREA V START CR - Offset Acquiring Area V-Start
6 Y - GAIN AREA H START
7 Y - GAIN AREA V START
8 CB - GAIN AREA H START
9 CB - GAIN AREA V START
10 CR - GAIN AREA H START
11 CR - GAIN AREA V START
1 Image AREA H WIDTH
13 Image AREA V HIGHT
14 Y - OFFSET TARTGET
15 CB OFFSET TARGET
16 CR OFFSET TARGET
17 Y - GAIN TARGET
18 CB - GAIN TARGET
19 CR - GAIN TARGET
0 OFFSET torelance
1 GAIN torelance
Group
custom (Aspect)
270
0 Scaler Horizontal
1 Scaler Vertical
 Connect
3 Position Horizontal
4 Position Vertical
5 Aspect Enable
Group
AutoPc Adjsut
280
0 AutoPCAdjustEnable
1 Frequency Step
 Frequency Threshold
3 Fine Phase
4 BLKDET
5 PHASEMSK
Group
Paneltype * Panel type check
290
0 GammaL/R-View
1 GammaL/R-Change
Group
composite (NtSc) composite / S-Video
500
0
1 Disp Dots
 H Back Porch
3 V Back Porch
4 Disp Line
Group
composite (PAL) composite / S-Video
501
0
1 Disp Dots
 H Back Porch
FuNctIoN
Y - Offset Acquiring Area H-Start
Position
Y - Offset Acquiring Area V-Start
Position
CB - Offset Acquiring Area H-Start
Position
CB - Offset Acquiring Area V-Start
Position
CR - Offset Acquiring Area H-Start
Position
Position
Y
YCBCR Level Acquiring Area
YCBCR Level Acquiring Area Height
Torelance of OFFSET Adj.
Torelance of GAIN Adj.
H-Scaler
V-Scaler
Link Edit 1: Link
H-Position
V-Position
Aspect Enable (0: On, 1: Off)
Auto-PC Adj Operation Enable if Un-
supported Signal Input
Frequency Steps of TotalDot
Total Dot Freqency Threshold
Do Phase Adj after Total Dot Adj.
Black Level Detection Area
Phase Detection Filter
Current Setting Check
Setting of Gamma
INItIAL
95
500
95
500
95
500
50
500
800
500
700
500
8
9
4
18
18
17
37
37
1
1
100
100
0
100
100
0
0
1
5
1
1
0
0
10
668
8
18
458
658
34
-43-
rANGe
Note
0 - 1000
0 - 1000
0 - 1000
If not used: use Y's value
0 - 1000
If not used: use Y's value
0 - 1000
If not used: use Y's value
0 - 1000
If not used: use Y's value
0 - 1000
0 - 1000
0 - 1000
0 - 1000
0 - 1000
0 - 1000
0 - 4095
0 - 4095
0 - 55
0 - 55
0 - 55
0 - 55
0 - 55
0 - 55
1 - 55
1 - 55
68-13
68-13
0-1
85-115
85-115
0-1
0 - 1
0: Enable, 1: Disable
0-3
0 - 10
0 [] <--- -----> 10[Not matched]
0: Executes Fine Phase, 1: Not
0 - 1
Execute
0 - 3
0: Effective All Bit,
1: Disable Lower 1 bit
0 - 3
: Disable Lower  bit, 3: Disable
Lower 3 bit
0: Gamma for L-Turn
0-0
0: Gamma for R-Turn * Read only
Sets L-Turn Gamma if the Value is
set to 0.
0-0
Sets R-Turn Gamma if the Value is
set to 0.
* Read only
0 ~ 4095
0 ~ 4095
0 ~ 4095
0 ~ 4095
* Read only
0 ~ 4095
0 ~ 4095

Advertisement

Table of Contents
loading

Table of Contents