Sanyo PLC-XU75A Service Manual page 38

Hide thumbs Also See for PLC-XU75A:
Table of Contents

Advertisement

Electrical Adjustments
Group/
IteM NAMe
Item
173 B-DCOffset-P5
174 B-DCOffset-P6
175 B-DCOffset-P7
176 B-DCOffset-P8
177 B-DCOffset-P9
178 B-DCOffset-P10
179 B-DCOffset-P11
180 B-DCOffset-P1
181 ENBX-R
18 ENBX-G
183 ENBX-B
184 DXOutPos
Group
Panel Service(6150/1060)
101
0 R-LCCOM
1 G-LCCOM
 B-LCCOM
3 R-LCCOM-Gain
4 G-LCCOM-Gain
5 B-LCCOM-Gain
6 R-LCCOM-Bright
7 G-LCCOM-Bright
8 B-LCCOM-Bright
9 R-LCCOM-Cent
10 G-LCCOM-Cent
11 B-LCCOM-Cent
1 R-ENBX-PW
13 G-ENBX-PW
14 B-ENBX-PW
15 R-DXIN
16 G-DXIN
17 B-DXIN
18 R-CLXIN
19 G-CLXIN
0 B-CLXIN
1 R-ENBX1IN
 G-ENBX1IN
3 B-ENBX1IN
Group
option
200
0 Logo Prohibition (Forced No
Brand)
1 RS3C Baudrate
 PJLink Enable
3 Shipping Setting
4 CABLE SW
PW Debug Command
5
Enable
6 Device Refresh Disable
7 Device Access Disable
0 Projector Time Reset
Lamp Warning Time
1
(NORMAL)
 Lamp Warning Time (ECO)
3 Lamp Warning Time (HIGH)
30 Lamp life test enable
31 Lmap On time(for life test)
3 Lamp Off time(for life test)
33 Lamp total time(for life test)
40 Lamp PWM PresAv 50Hz
41 Lamp PWM PresAv 60Hz
FuNctIoN
Logo Prohibition (0: Menu, 1: Forced,
: China, 3-9: not used)
Baud Rate
PJLink
Long Cable
Lamp Life at Normal Mode (Warning
Time at Normal)
Lamp Life at Eco Mode (Warning
Time at Eco)
Lamp Life at High Mode (Warning
Time at High)
For test purpose
For test purpose
For test purpose
Lamp PWM PRES0 Setting (AV
50Hz)
Lamp PWM PRES0 Setting (AV
60Hz)
INItIAL
0/0
0/0
0/0
0/0
0/0
0/0
0/0
0 / 
0
0
0
0
386
350
360
191
191
191
0
0
0
14
14
14
1
1
1
9
9
9
9
9
9
7
7
7
0
0
0
0
0
0
0
0
-
-
-
-
80
67
-38-
rANGe
Note
0-511
Scan Direction (Front/Rear)
0-511
Scan Direction (Front/Rear)
0-511
Scan Direction (Front/Rear)
0-511
Scan Direction (Front/Rear)
0-511
Scan Direction (Front/Rear)
0-511
Scan Direction (Front/Rear)
0-511
Scan Direction (Front/Rear)
0-511
Scan Direction (Front/Rear)
0-17
0-17
0-17
0-1
0-511
*Common Center Adjustment
0-511
*Common Center Adjustment
0-511
*Common Center Adjustment
0-55
0-55
0-55
0-55
0-55
0-55
0-63
0-63
0-63
0-17
0-17
0-17
0-55
Link with No.18
0-55
Link with No.19
0-55
Link with No.0
0-55
Link with No.15
0-55
Link with No.16
0-55
Link with No.17
0-55
0-55
0-55
0 - 
Effective after AC On
0: 1900bps, 1: 9600bps, :
0 - 
11500bps
0: Disable 1: Enable
Default set when the value is set to
0 - 0
10
0 - 10
0: Disable, 1: Enable
0:Disable (Serial Command Eanble)
0 - 1
1: Enable (PW Debug Mode)
0:Enable, 1:Disable
0 - 1
No last memory
0:Enable (Normal), 1:Disable
0 - 1
No last memory
Projector Time is cleared when the
0 - 0
value is set to 10
500 -
8000
500 -
8000
500 -
8000
0:Disable 1:Enable, for safety test
only
0-55
0-55

Advertisement

Table of Contents
loading

Table of Contents