Sanyo PLC-XU75A Service Manual page 39

Hide thumbs Also See for PLC-XU75A:
Table of Contents

Advertisement

Electrical Adjustments
Group/
IteM NAMe
Item
4 Lamp PWM PresUnlock
43 Lamp PWM PresPcA
44 Lamp PWM PresPcB
45 Lamp PWM PrefHAv 50Hz
46 Lamp PWM PrefHAv 60Hz
47 Lamp PWM PrefHUnlock
50 Lamp Replacement Display
51 Filter Warning Display
5 Lamp Counter reset Times
54 Factory Default Execute
Times
55 Motor Disable
56 Menu Position
57 Menu Position
59 Source Search Enable
60 Language Default setting
61 Screen Aspect HL
6 Screen Aspect HR
63 Screen Aspect VT
64 Screen Aspect VB
70 RC Mode
Group
option (signal)
201
0 FrameLock Option
 Field Sense Invert Enable
3
4 Sub Image Enable
6 Zoom Accelerator Enable
7 DZoom Reset by Keystone
8 Stability Count
Sensivity for Signal Lost
9
(HSYNC)
Sensivity for Signal Lost
10
(VSYNC)
11 Keystone Filter Center Value Reference Value
Group
Spread Spectrum
205
0 Spread Spectrum Enable
1 Spread Spectrum Frequency
 Spread Spectrum Amplitude
Group
Lamp contorl
210
0 DIMMER_CTRL_LEVEL1
1
DIMMER_CTRL_LEVEL
 DIMMER_CTRL_LEVEL3
3 DIMMER_CTRL_LEVEL4
4 DIMMER_CTRL_LEVEL5
FuNctIoN
Lamp PWM PRES0 Setting (No
Signal)
Lamp PWM Frequency Setting A
Lamp PWM Frequency Setting B
Lamp PWM PREF0 Setting (AV
50Hz)
Lamp PWM PREF0 Setting (AV
60Hz)
Lamp PWM PREF0 Setting (No
Signal)
Lamp Warning Display On / Off
Filter Warning Display On / Off
Reset Times of Lamp Counter
Reset times of Fanctory Default
Motors Disable
Move menu (X asis)
Move menu (Y asis)
Source Search Enable (0:Disable 1:
Enable)
Language Default setting
Screen Aspect H left
Screen Aspect H right
Screen Aspect V top
Screen Aspect V bottom
RC Mode
Count Value of V-missing
Only used this value for No Signal
Judgement(Hz)
Only used this value for No Signal
Judgement(Line)
Luminance Level 1 Data for Dimmer:
Dim Level 1 at the less than the
Value
Luminance Level  Data for Dimmer:
Dim Level  at the less than the
Value
Luminance Level 3 Data for Dimmer:
Dim Level 3 at the less than the
Value
Luminance Level 4 Data for Dimmer:
Dim Level 4 at the less than the
Value
Luminance Level 5 Data for Dimmer:
Dim Level 5 at the less than the
Value
INItIAL
65

3
5000
5000
5000
1
1
0
0
0
0
0
0
0
105
105
45
45
1
1
0
1
0
0
5
350
3
16
1
80
100
9
18
6
35
44
-39-
rANGe
Note
0-55
0-55
0-55
0-65535
0-65535
0-65535
0 - 1
1: On, 0: Off
0 - 1
1: On, 0: Off
0 - 55
Read only
0 - 55
Read only
0 - 1
0: On, 1: Off
0 - 104
0 - 104
0 - 1
0-1
0-104
0-104
0-104
0-104
0-1
0: FrameLockOFF at PC signal
1: FrameLockON at PC signal and
0 - 1
47Hz (Vfreq) ~ Panel frequency of
input signal
Reverse Processing of
FLDINVSetting Value
0: Disable - Used FLDINV Setting
0 - 1
Value
1: Enable - Used Reversed FLDINV
Setting Value
0:Disable (Service Adjustment
Dsiable, Used all the Center Values
0 - 1
1:Enable (Service Adjustment
Enable)
0:Zoom Accelerator OFF ,
0 - 1
1:Zoom Accelerator ON
No last memory
0:Enable (Normal), 1:Disable (Dzoo
is not cancelled even if Keystone is
0 - 1
cancelled)
No last memory
0 - 55
0 - 3767
0 - 55
0 - 30
0 - 1
0: Off, 1: On
0 - 500
0 - 300
0 - 55
0 - 55
0 - 55
0 - 55
0 - 55

Advertisement

Table of Contents
loading