Electrical Requirements; Cabinet Requirements - Bosch hei80 Installation Instructions Manual

Electric and induction ranges
Table of Contents

Advertisement

Available languages

Available languages

Electrical
Requirements
Refer to data plate for more information. See the product
"Data Plate" in the section on Service in this manual.
We recommend that the range be installed with a
power cord set (not supplied). The electrical rating
of the power cord set must be 120/240 volt, 30 amperes
minimum. The power cord set shall be marked "For Use
with Ranges." Always use a new power cord.
Note: In Canada, the range is shipped from the factory with
the range power cord already installed.
Electrical kW Rating
Ranges are dual rated for use on either 120/240 VAC or
120/208 VAC. Check the data plate for the kW rating.
Reference the kW rating in the table below to determine
amperage requirements.
Verify that wiring to house is adequate Contact your local
utility company to verify that the present electric service to
your home is adequate. In some instances, the size of the
wiring to the house andservice switch must be increased to
handle the electrical load demanded by the range.
Verify that wiring inside house is adequate. Most wiring
codes require a separate circuit with separate disconnect
switch and fuses either in the main entrance panel or in a
separate switch and fuse box
The range requires a minimum of a three wire 120/240 or
120/208 volt, 40 or 50 AMP, 60 Hz AC circuit. Check local
codes for proper amperage ratings.A four wire connection
is preferred. Most local building regulations and codes
require that electrical wiring be done by licensed
electricians. Be sure to install your range according to the
electric codes in place in your region.
VOLTS
HZ
RATING
A/C
KW
120/240
60
13.0
120/240
60
13.8
120/208
60
9.8
120/208
60
10.4
CIRCUIT
BREAKER
40 or 50 amps*
40 or 50 amps*
40 or 50 amps*
40 or 50 amps*
* Varies by location. Check local codes.
Electric Outlet Location
There is a recessed area in the lower structure of the range
back to accomodate the electrical outlet box. Use the
diagram below to make sure your installation in properly
prepared for the range.
Cabinet Requirements
This unit is designed for installation near adjacent walls and
projecting surfaces constructed of combustible materials.
Prepare the countertop and cabinets.
Allow a minimum
of 30" (76.2 cm) between
cabinets
where range is to be installed. No side clearance is
required in the U.S. (In Canada, 12 mm clearance is
required from range sidewalls to cabinets). Height is set by
adjusting the range legs (see later section, "Complete the
installation".
iii¸ i! il
ii
Note: The slide-in
range can also replace
a
freestanding
range. In this case, verify that the opening is
at least 30" (76.2 cm).
English 6

Advertisement

Table of Contents
loading

This manual is also suitable for:

Heip0Hiip0

Table of Contents