Ice Maker - Siemens GS..D SERIES Instructions For Use Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 27
en
Fault
Freezer compartment door
was open for a long time;
temperature is no longer
reached.
Appliance is not cooling,
temperature display and light
are lit.

Ice maker

Fault
The ice maker doesn't work. Ice maker is not connected
44
Possible cause
The evaporator (refrigeration
generator) in the NoFrost
system is covered in thick ice
and can no
longer be defrosted fully
automatically.
Showroom mode is
switched on.
Possible cause
to the power supply.
The ice maker is switched
off.
Ice maker is not receiving
any fresh water.
The freezer compartment
temperature is too warm.
Supply hose is kinked or
crushed. Fig. (
Remedial action
To defrost the evaporator, remove the frozen
food with the compartments, insulate well
and store in a cool location.
Switch off the appliance and move it away
from the wall. Leave the appliance door open.
After approx. 20 min. the condensation begins
to run into the evaporation pan,
at the rear of the appliance. Fig. '
To prevent the evaporation pan
from overflowing in this case,
mop up the condensation with a sponge.
The evaporator is defrosted when the water
stops running into the evaporation pan. Clean
the interior. Switch the appliance
back on again.
Hold down alarm button, Fig "/5, for
10 seconds until an acknowledgement signal
sounds.
After a short time check whether your
appliance is cooling.
Remedial action
Call the customer service.
Switch on the ice maker (see "Ice maker").
Ensure that the water has been connected
properly.
Check freezer compartment temperature and,
if required, set slightly colder.
Ensure that the supply hose is installed
correctly.