Configurations are created by installing or removing the pad frame's extension arms, by
repositioning or removing the movable pad mounts, and by connecting or disconnecting the
vacuum hoses to certain vacuum pads. Always assemble the pad frame in a symmetrical
arrangement, to keep the lifter balanced (see illustration).
To support the maximum load weight, all vacuum pads must be installed on the pad frame and
all vacuum hoses must be connected to the vacuum pads. To support the largest load
dimensions, all extension arms must also be installed on the pad frame. To support smaller
weights and dimensions, some extension arms or vacuum pads may be removed, and the
corresponding vacuum hoses may be disconnected,
sufficient capacity to support the load in question
WARNING: Removing or disconnecting any vacuum pad reduces lifter's load
To calculate the load capacity when some vacuum pads are removed, consult the Per-Pad Load
Capacity (see SPECIFICATIONS) and multiply by the number of pads currently in use. Make sure
all vacuum hoses are secure and routed to avoid being pinched, snagged, abraded or otherwise
damaged while the lifter is in operation.
WARNING: Make sure all vacuum hoses are coiled or routed so they cannot
To Connect/Disconnect Vacuum Hoses
The vacuum hose for each vacuum pad is connected to or
disconnected from the vacuum system by means of a quick
connector. To connect the vacuum hose, push the male and
female ends of the connector together until they lock. To
disconnect the vacuum hose, move the release ring on the female
end away from the male end until the connector separates. Then
clip the free end of the connector to the spring clip on the
extension arm.
Note: Whenever a quick connector is disconnected, the corresponding vacuum pad does not
contribute to the load capacity, whether or not the pad is mounted on the pad frame.
Rev 3.0/10-06
capacity.
become entangled, kinked or punctured during rotation or tilt.
QUADRA-TILT ROTATOR • DC-VOLTAGE
provided that the lifter still has
.
QUICK CONNECTOR
1 MALE END
2 RELEASE RING
3 FEMALE END
Page 6