Woods MRTA611LDC Instructions Manual page 14

Quadra-tilt rotator dc-voltage with dual vacuum system
Table of Contents

Advertisement

T
L
O
IFT AND
About the Tilt Linkage
WARNING: Make sure load is positioned correctly on lifter; unbalanced loads
The lifter's tilt linkage is designed to automatically hold a balanced load in either the upright or
the flat position. However, an unbalanced load may tilt unexpectedly from the flat position to the
upright position or vice versa. This could result in load damage or injury to anyone positioned in
the tilt path of the load. To minimize the potential for these problems, make certain
lifting any load
that it has allowable characteristics (see INTENDED USE: L
and is attached correctly to the lifter (see T
Engaging or Disengaging Optional Tilt Locks
When a lifter is equipped with tilt locks, they can be used to prevent unexpected tilting motion.
Since the lifter is designed to maintain either the vertical or the horizontal pad frame orientation
when correctly loaded, the tilt locks should only be needed if the operator is not able to maintain
control of the load using the control handle or other appropriate means. For example, if the lifter
is being used to install glass in a multi-story building, engaging the tilt locks would prevent the
load from accidentally tilting due to wind loads or other causes of incidental loading. Tilt locks
are intended as a secondary safety device and do not eliminate the need to center the load
correctly on the pad frame (see T
preceding).
CAUTION: Failure to center load correctly may
damage tilt locks or other lifter
components.
To engage the tilt locks, first make sure the pad frame is
oriented in either the horizontal or the vertical position.
Then turn the T-handles on the spring plungers to the
engaged position, making sure that the noses of both spring
plungers are fully inserted in the notches on the plates where
the lifter's tilt linkage attaches. To disengage the tilt locks,
pull the T-handles outward and turn them to the disengaged
position, making sure that the noses of both spring plungers are
fully retracted from the slots before attempting to tilt the pad
frame.
Load Capacity and the Warning Light
The lifter's Load Capacity is rated at a vacuum level of 16" Hg [-54 kPa] (see SPECIFICATIONS).
After the lifter has attained this level, the vacuum pump turns off automatically, to conserve
battery energy. At the same time, the low vacuum warning light turns off, to indicate that the
lifter is ready to lift the maximum load weight.
WARNING: Never attempt to lift load while red warning light is illuminated.
Do not attempt to lift the load while the warning light is illuminated; such an attempt could result
in a load release and possible injury to the operator.
Rev 3.0/10-06
M
L
OVE THE
OAD
may tilt unexpectedly.
A
O
PPLY THE
QUADRA-TILT ROTATOR • DC-VOLTAGE
A
P
O
PPLY THE
ADS TO A
P
L
: Positioning the Lifter on the Load
ADS TO A
OAD
C
OAD
HARACTERISTICS
L
preceding).
OAD
SPRING PLUNGERS
1 NOSE
2 T-HANDLE - ENGAGED
3 T-HANDLE - DISENGAGED
prior to
)
Page 13

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents