Download Print this page

Ikelite SLR-DC 6855.10 Instruction Manual page 6

For olympus e-510/e-520

Advertisement

C C h h o o o o s s i i n n g g a a P P o o r r t t
• With the lens on the camera extended
to full length, measure from front of
camera to face of lens.
• Select the appropriate port based on the
lens type and length.
• Maximum lens diameter accommodated
is 8.4cm (3.3")
• Maximum lens diameter when using
Measure
zoom or focus clamp 7.1 cm (2.8").
Standard clamp - 2.8".
# 5509.28 - 2.8" to 3"
D D O O M M E E P P O O R R T T
#5503..........Wide angle 28mm to 1 7mm
....................or lens up to 7.6cm (3") in length
#5503.20 ....Nikon 1 8 & 20mmD lenses
#5503.50 ....Lens 7.6-1 0.1 cm (3-4")
#5503.55 ....Lens 8.9-1 1 .4cm (3.5-4.5")
#5503.80 ....Lens 1 0.1 -1 2.7cm (4-5")
#5503.85 ....Lens 1 2.7-1 5.2cm (5-6")
M M a a i i n n t t e e n n a a n n c c e e
The Ikelite Housing should be given the same care and attention
as your other photographic equipment. In addition to normal
maintenance we recommend that the housing be returned to
Ikelite periodically to be checked and pressure tested.
1 . D D o o N N o o t t leave the camera and housing in direct sunlight for
prolonged periods. Heat may damage the camera.
2. D D o o N N o o t t ship the camera in the housing.
3. Before using the housing, always check the tightness of the
s s e e t t s s c c r r e e w w in each control knob.
Check each c c o o n n t t r r o o l l g g l l a a n n d d penetrating the housing to make sure
they are tight. There is a slight chance that either could vibrate
loose during travel.
4. Keep the back and port o'ring clean and lightly lubricated. To
lubricate remove the o'ring from the back. Put a small amount
of lkelite lubricant on your fingers. Draw the o'ring through
your fingers to apply a light coating of lubricant. Only apply
enough lubricant to make the o'ring feel slick. D D o o N N o o t t s s t t r r e e t t c c h h
t t h h e e o o ' ' r r i i n n g g . This light coating of lubricant will help to keep the
o'ring from drying out and will help to show a dark sealing line
when the housing back is properly sealed.
5. Keep the area where the o'ring fits and the sealing surface clean.
6. Rinse the housing exterior thoroughly in fresh water after each
salt water use. Depress push buttons several times during rinse.
Dry with a soft cloth. Dry port to eliminate water spotting.
After several uses in salt water soak the housing in a mild soap
solution, rinse and dry.
7. If removing a housing push button, D D o o N N o o t t re-use the E-clip.
Contact Ikelite for replacement E-clips (part #031 9.1 2).
C C A A U U T T I I O O N N : :
N N e e v v e e r r u u s s e e s s p p r r a a y y l l u u b b r r i i c c a a n n t t s s a a s s t t h h e e p p r r o o p p e e l l l l a a n n t t
i i n n g g r r e e d d i i e e n n t t c c a a n n c c a a u u s s e e t t h h e e p p l l a a s s t t i i c c h h o o u u s s i i n n g g t t o o c c r r a a c c k k . .
21
23
P P o o r r t t s s C C o o n n t t i i n n u u e e d d
F F L L A A T T P P O O R R T T
For standard, macro, and telephoto lenses.
Due to refraction flat ports reduce the angle-of -coverage of a lens
and at the same time enlarge the image. This makes the flat port
ideal when using standard, macro or zoom lenses to shoot small
subjects. Note that if a port is long enough to accommodate the
full length of a 1 :1 macro lens, the lens may vignette when used at
infinity. If access to the lens' full range is desired, then select a
dome port instead.
F F L L A A T T P P O O R R T T
5501 . . . . . . Lens up to 6.3cm (2.5")
5502 . . . . . . Lens 6.3-8.9cm (2.5-3.5")
5502.41. . . . Lens 7.9-1 0.4cm (3.1 -4.1 25")
5505 . . . . . . Lens 8.9-1 1 .4cm (3.5-4.5")
5505.45. . . . Lens 1 0.4-1 3cm (4.1 -5.1 25")
5505.5. . . . . Lens 1 1 .4-1 4cm (4.5-5.5")
5505.58. . . . Lens 1 3-1 5.5cm (5.1 -6.1 25")
F F L L A A T T P P O O R R T T W W I I T T H H F F O O C C U U S S
For long lenses whose focus collar extends beyond the housing
focus. Telephoto lenses longer than 1 35mm are not recommended.
5506 . . . . . . Lens 8.9-1 1 .4cm (3.5-4.5")
5506.5. . . . . Lens 1 1 .4-1 4cm (4.5-5.5")
5507 . . . . . . Lens 1 4-1 6.5cm (5.5-6.5")
5508 . . . . . . Lens 1 6.5-1 9cm (6.5-7.5")
5508.05. . . . Nikor 1 05mm lens only
C C o o n n t t r r o o l l M M a a i i n n t t e e n n a a n n c c e e
Ikelite controls are designed to provide years of reliable service
with minimal maintenance.
1 . Push button controls require no maintenance other than rinsing
in fresh water after saltwater use. If a push button control
becomes difficult to push or if it sticks when depressed, soak the
housing in luke warm fresh water. After a few minutes operate
the push button. If this does not correct the problem, return the
housing to Ikelite for maintenance.
housing
2. Some of the controls have long shafts. These controls can be
pulled out, exposing the shaft (see drawing).
To lubricate the control, gently pull on the knob until the
stainless steel shaft is exposed. Lightly lubricate the shaft, then
move the shaft in and out several times. This will lubricate the
x'ring in the Ikelite control gland. This should be done before
using the housing after a prolonged storage period, or once a
week when the housing is in use.
22
lubricate shaft
pull out to
expose shaft
24

Advertisement

loading