Appendix C. Command Package For The Message Of Receiving Tag Code - Promag WEC200 User Manual

Wiegand to ethernet converter/controller
Table of Contents

Advertisement

Appendix C. Command Package for the
Message of Receiving Tag code
When user presents his/her card on the Weigand reader, if tag is read OK, the reader will send the tag code to
WEC200 via Wiegand interface and then transmit to host PC.
Before transmitting to host PC, the tag code will be packaged by WEC200 in a pre-defined format, and the
format is different between WEC200-00 and WEC200-01.
To detail this, for example, if the tag code is FC177ID25111, then for WEC200-00 it will be packaged as
02h
57h
46h
Hex
F
W
The package starts with STX (02h), and end with CR (0Dh).
The W (57h) is the message code.
For WEC200-01, it will be packaged as:
02h
46h
43h
Hex
F
C
The package starts with STX (02h), and end with CR (0Dh).
No message code.
The data after TAB (09h, including TAB) is reserved for TRU uses.
43h
31h
37h
37h
C
1
7
7
31h
37h
37h
49h
1
7
7
I
49h
44h
32h
35h
I
D
2
5
44h
32h
35h
31h
D
2
5
1
19
31h
31h
31h
0Dh
1
1
1
31h
31h
09h
44h
1
1
D
09h
53h
0Dh
S

Advertisement

Table of Contents
loading

Table of Contents