Commissioning; Preparing The Service Pc - Baudisch CP-CAM-AHD ECO / MAX Manual

Table of Contents

Advertisement

Baudisch.CP-CAM-AHD ECO / MAXI
4.

Commissioning

4.1.

Preparing the Service PC

For the CP-CAM can be accessed after installation, an IP address in the address range of your
network must be assigned to this. This setting can be made with a directly to the TouchMe
connected PC / laptop and an external 24V power supply for the TouchMe.
!
!
To establish a connection with the CP-CAM, it is necessary that the PC / laptop use is
temporarily set to an IP adresse in the range of the CP-CAM. On delivery, the 192.168.1.xxx
address range is defined.
The Baudisch.CP-CAM-AHD is set to the address 192.168.1.220 by factory.
To prepare your service PC, proceed as follows:
IP address and address range of the PC / laptop to temporarily change
20131030SC_HB-EN_CP-CAM-AHD-Steel.doc
Öpen the properties of your LAN connection
o
Open the properties of the Internet Protocol (TCP/IP)
o
Include your LAN connection an IP address in the range 192.168.1.xxx . Note
o
the default IP address of the CP-CAM.
Version 1.1 - Stand: 19.11.2013