Advertisement

Quick Links

History:
Version
1.0
1.1
Released last version:
geprüft
geprüft
geprüft
geprüft
gesehen
freigegeben
20131030SC_HB-EN_CP-CAM-AHD-Steel.doc
Baudisch.CP-CAM-AHD ECO / MAXI
Date
Name
30.10.2013
M.Schmidt
19.11.2013
M.Schmidt
Date
Name
TT.MM.JJJJ
Modification
First draft
Modification of the factory default values
Unit
KZZ
Signature
DEV
PF
VT
Kunde
FE
GL
1 / 1
Manual
s/15.05.2014

Advertisement

Table of Contents
loading

Summary of Contents for Baudisch CP-CAM-AHD ECO / MAX

  • Page 1 Baudisch.CP-CAM-AHD ECO / MAXI Manual History: Version Date Name Modification 30.10.2013 M.Schmidt First draft 19.11.2013 M.Schmidt Modification of the factory default values Released last version: Date Name Unit Signature geprüft TT.MM.JJJJ geprüft geprüft geprüft Kunde gesehen freigegeben 20131030SC_HB-EN_CP-CAM-AHD-Steel.doc 1 / 1...
  • Page 2: Table Of Contents

    Optional Accessories ........................7 Commissioning ..........................9 4.1. Preparing the Service PC ......................9 4.2. Connect the Baudisch.CP-CAM-AHD ..................10 4.2.1. Operating at a SIP door module MAXI / PLUS or TouchMe MAXI ..........10 4.2.2. Stand-alone operation ......................... 10 Configuration ..........................
  • Page 3: General

    Baudisch.CP-CAM-AHD ECO / MAXI Version 1.1 - Stand: 19.11.2013 General 2.1. Symbols and Highlighting Warning of hazardous electrical voltage. This symbol indicates important instructions that you should follow in any case, to avoid injury or damage to or malfunction of the product.
  • Page 4: Product Description

    The MAXI version also has a built-in infrared illumination with which people and objects are well illuminated in total darkness. The connection done comfortably at the AUX port of the Baudisch.SIP door module MAXI / PLUS or the Baudisch.TouchMe MAXI.
  • Page 5: System Overview

    Baudisch.CP-CAM-AHD ECO / MAXI Version 1.1 - Stand: 19.11.2013 3.2. System overview Baudisch. Baudisch. Baudisch. Baudisch. Baudisch.SIP DoorModule Diode LED-Module MAXI / ECO DisplayModule KeypadModule 16B MatrixModule only MAXI Baudisch. Baudisch. Baudisch. Baudisch. Emergency ButtonModule CP-CAM Central call Module ButtonModule IP Network / LAN Baudisch.
  • Page 6: Scope Of Delivery

    Baudisch.CP-CAM-AHD ECO / MAXI Version 1.1 - Stand: 19.11.2013 3.4. Scope of delivery Article-No. Name / Description 36-0243 Baudisch.CP-CAM-AHD-ECO Complete module with V4A front panel and IP camera 36-0242 Baudisch.CP-CAM-AHD-MAXI Complete module with V4A front panel, IP camera and infrared illumination 20131030SC_HB-EN_CP-CAM-AHD-Steel.doc...
  • Page 7: Optional Accessories

    Baudisch.CP-CAM-AHD ECO / MAXI Version 1.1 - Stand: 19.11.2013 3.5. Optional Accessories Article-No. Name / Description 33-1507A (1-fold, 1x1) Flush-mounting box 33-1507B (2-fold, 2x1) 33-1507C (3-fold, 3x1) 33-1507D (4-fold, 4x1) 33-1507H (5-fold, 5x1) 33-1507E (4-fold, 2x2) 33-1507F (6-fold, 3x2) 33-1507G (8-fold, 4x2)
  • Page 8 Baudisch.CP-CAM-AHD ECO / MAXI Version 1.1 - Stand: 19.11.2013 Article-No. Name / Description 33-1000 (MAXI) Baudisch.SIP door module MAXI / PLUS 33-1384 (PLUS) 33-1119 (V4A front panel) 33-1310 Baudisch.TouchMe MAXI 33-0901E Baudisch.CP-CAM Supply Interface 36-0213 Baudisch.CP-CAM Viewer 20131030SC_HB-EN_CP-CAM-AHD-Steel.doc 8 / 8...
  • Page 9: Commissioning

    To establish a connection with the CP-CAM, it is necessary that the PC / laptop use is temporarily set to an IP adresse in the range of the CP-CAM. On delivery, the 192.168.1.xxx address range is defined. The Baudisch.CP-CAM-AHD is set to the address 192.168.1.220 by factory. To prepare your service PC, proceed as follows: •...
  • Page 10: Connect The Baudisch.cp-Cam-Ahd

    • Connect the CP-CAM-AHD with the supplied cable with the ethernet output / CP-CAM Out of the Baudisch.SIP door module MAXI / PLUS or the Baudisch.TouchMe MAXI. • Connect the SIP door module MAXI / PLUS either with a PowerOverEthernet (PoE) switch or with a 24V DC power supply and a ethernet switch or connect the Baudisch.TouchMe MAXI with a 24V DC power supply and a ethernet switch.
  • Page 11: Configuration

    Baudisch.CP-CAM-AHD ECO / MAXI Version 1.1 - Stand: 19.11.2013 Configuration 5.1. Log in to the Web Interface The IP camera has an integrated web server which allows users to log in via a standard web browser. In order to login on an IP Camera for the first time with its default settings, proceed as follows: •...
  • Page 12: Ip Settings

    Baudisch.CP-CAM-AHD ECO / MAXI Version 1.1 - Stand: 19.11.2013 5.1.1. IP Settings Click on S etup at the menubar. Click on Basic Setup -> 3 TCP/IP in the left browser menu. IPv4 Address Configuration - Ethernet: „Obtain IP address via DHCP”: automatic configuration via DHCP server.
  • Page 13: User Management

    Baudisch.CP-CAM-AHD ECO / MAXI Version 1.1 - Stand: 19.11.2013 5.1.3. User Management Click on S etup at the menubar. • Click on Basic Setup -> Users in the left browser menu. • To create a new user, proceed as follows: Click on Add under the User List.
  • Page 14 Baudisch.CP-CAM-AHD ECO / MAXI Version 1.1 - Stand: 19.11.2013 With the specification of parameters in the URL, it is possible to bypass the default settings that are defined in chapter 5.1.2 The following parameters can be specified directly in the URL: •...
  • Page 15: Accessing The Video Stream With A Snom Ip-Phone

    Baudisch.CP-CAM-AHD ECO / MAXI Version 1.1 - Stand: 19.11.2013 5.3. Accessing the video stream with a SNOM IP-Phone To access the video stream with a SNOM 760, 820 or 821 IP-Phone it is necessary to build a xml file on the IP camera.
  • Page 16 Baudisch.CP-CAM-AHD ECO / MAXI Version 1.1 - Stand: 19.11.2013 Click on „Apply“ followed by „Save“ at the top of the window to apply and save the configuration identity.. In the next step the settings for the automatic image transmission from the integrated IP Camera are made.
  • Page 17: Firmwareupdate

    Baudisch.CP-CAM-AHD ECO / MAXI Version 1.1 - Stand: 19.11.2013 5.4. Firmwareupdate The latest firmware for the camera module can be downloaded directly from AXIS Please visit http://www.axis.com/techsup/ and download the firmware for the M1004-W network camera. 5.5. Reset to factory default To restore the factory settings, proceed as follows: •...
  • Page 18: Product Details

    Baudisch.CP-CAM-AHD ECO / MAXI Version 1.1 - Stand: 19.11.2013 Product Details 6.1. Specifications Ports and Interfaces Male connector 4 pin X1 10 / 100 MBit Ethernet Male connector 5 pin X2 Power 24V DC / GPIO Male connector 3 pin X6...
  • Page 19 Baudisch.CP-CAM-AHD ECO / MAXI Version 1.1 - Stand: 19.11.2013 Features Camera model AXIS M1004-W Image sensor ¼“ CMOS (progressive scan RGB) Lense ECO: 2.8mm, F2.0, 80° horizontal viewing angle, IR Filter MAXI: 2,5mm, F2.0, 83° horizontal viewing angle Light sensitivity 1.2 –...
  • Page 20 Baudisch.CP-CAM-AHD ECO / MAXI Version 1.1 - Stand: 19.11.2013 CE conformity DIN EN 55022 2011-12 Information technology equipment- Radio disturbance characteristics- Limits and methods of measurement DIN EN 61000-6-2 Generics standards – Immunity for industrial environments 2006-03 Generic standards – Emission standard for residential,...
  • Page 21: Connector Description

    6.2. Connector description Don’t connect the Baudisch.TouchMe to supply voltages of 110 / 230V AC ! If this isn’t complied with, in the absence of grounding the module may be damaged so that power is applied to housing and loss of life...
  • Page 22: Technical Drawings

    Baudisch.CP-CAM-AHD ECO / MAXI Version 1.1 - Stand: 19.11.2013 6.3. Technical drawings 6.3.1. Baudisch.CP-CAM-AHD-Steel ECO 20131030SC_HB-EN_CP-CAM-AHD-Steel.doc 22 / 22 s/15.05.2014...
  • Page 23: Baudisch.cp-Cam-Ahd-Steel Maxi

    Baudisch.CP-CAM-AHD ECO / MAXI Version 1.1 - Stand: 19.11.2013 6.3.2. Baudisch.CP-CAM-AHD-Steel MAXI 20131030SC_HB-EN_CP-CAM-AHD-Steel.doc 23 / 23 s/15.05.2014...
  • Page 24: Support

    Baudisch.CP-CAM-AHD ECO / MAXI Version 1.1 - Stand: 19.11.2013 6.4. Support For questions and problems during startup, please contact our support department: support@stentofonbaudisch.com Manufacturing Baudisch Electronic GmbH Im Gewerbegebiet 7-9 D-73116 Wäschenbeuren Tel.: +49 7172 / 92613-0 Fax: +49 7172 / 92613-30 Mail: vertrieb@baudisch.de...

Table of Contents