If you cannot contact Any optional extras or kit fitted subsequently must be them, call the Fire Brigade. original Cosmogas spares. This appliance must only be used for the purpose it has If you smell pruducts of the combustion been expressly designed for: heating water for closed ...
All its components can easily control. be separated into similar and Thanks to on-going research completely recyclable parts. carried out by COSMOGAS, this product has been conceived and is considered to be the best in 2.2 - Description of models NOVADENS XXYYYY “...
4 - fUNCTIONS Of ThE APPLIANCE 4.1 - Intended use E- NOVADENS -- “0834”. By means All the boiler versions described of this boiler, a system can be created previously can be connected to a and functions of the for the production of instant domestic room thermostat for the setting of hot water and a heating system the heating.
4 - fUNCTIONS Of ThE APPLIANCE 4.2 - Characteristic curves of heating system’s residual head Each standard boiler is fitted with its own specific circulator pump. The residual head at the boiler connections is shown in graph form in figures 6. On demande, we can supply the boiler with a 7 m head pump (see fig.7).
5 - INSTALLATION 5.1 - Opening the packaging The appliance is supplied in a box. Open it up following the instructions given on the closing flaps. 5.2 - Dimensions and clearances for installation Leave an area free around the boiler for carrying out installation or maintenance activities, as shown in figure 9.
6 in the ON position (see There are two possible situations: chapter 7.5). CAUTION!!! COSMOGAS By means of this setting, the boiler will A - the gas type and the supply cannot be held responsible for any...
5 - INSTALLATION 5.8 - Assembling the appliance Refer to figure 11: place the paper template, provided with the appliance, against the wall; ensure that the template is square with the room; mark holes for the wall dowel plugs and the hydraulic fittings;...
5 - INSTALLATION 5.10 - Condensation discharge The boiler is equipped internally with a trap for the evacuation of condensation (see figure 1, detail 40) and so as to prevent the leakage of combustion products, whose end corresponds with pipe “B” shown in figure 13. This end must be conveyed to another smell-control trap (figure 14, detail “F”) so as to prevent the return of bad smells in the room (the smell-control trap...
“B”), so as to safeguard the appliance from any blockage in the domestic water circuit. In order to facilitate installation, a softener may be request to COSMOGAS, with a specific installation kit. Reference of figure 17 A = Box tool’s control...
5 - INSTALLATION 5.14 - Electrical 5.14.1 - Connecting the mains electricity by a three- pole electrical cable with double connections: the power supply insulation and a minimum cross section of 1.5 mm2, resistant to overview cable a minimum temperature of 70°C (feature T).
5 - INSTALLATION 5.14.2 - Choosing To connect the cable of the outside remove the boiler casing according temperature sensor, proceed as to the instructions given in section the room 8.2; follows: lay a bipolar electrical cable with a ...
5 - INSTALLATION 5.14.5 - CR04 Once the remote control has been connected, all the room temperature remote time control adjustments and domestic water temperature operations must be (optional) carried out directly on the same. Accordingly, remember to closely The CR04 time control is a room follow the instructions contained on thermostat capable of interacting the CR04 remote control.
The first time the boiler is started up, the anti-Legionnaires cycle is also started after 2 hours of running. 1 COSMOGAS boiler 9 Check valve (to be fitted by 2 B70C type storage tank (on installer) request)
lay the bipolar cable with a minimum 1.5mm2 section which goes from the boiler to the temperature sensor of the 1 COSMOGAS boiler 9 Cold water inlet storage tank and connect it on the boiler 10 Supply and return for storage to terminals “15”...
5 - INSTALLATION 5.17 - Venting systems CAUTION!!! All venting systems must be connected in compliance with current national and local standards. CAUTION!!! Under determinate conditions, the temperature of the appliance’s flue gases may reach 110°C. Therefore, use plastic piping capable of resisting this temperature.
5 - INSTALLATION 5.17.1 - “Split 80/80PP” system (polypropylene) The standard appliance is not supplied with fittings for connecting flue gas discharge outlets/ air intakes. A special kit is available on request for connecting the boiler to the “split 80/80PP system”, to be installed following figure 23.
5 - INSTALLATION 5.17.2 - “Split 80/80PP” system: available accessories Some of the most commonly used accessories for installing the split system of flue gas discharge/air intake 80/80PP are listed below; a much wider range however can be found in the special catalogue: (the number after the code refers to the part in the following drawings) 62617053 - No.
5 - INSTALLATION 5.17.3 - “Split 80/80PP” system: installation examples Two installation examples can be seen in figure 26: - discharge into chimney with collection of condensation at base of the chimney. The horizontal part of the flue gas discharge side must be pitched towards the “T”...
5 - INSTALLATION 5.17.4 - “Coaxial 60/100PP” system (polypropylene) The standard appliance is not supplied with fittings for connecting flue gas discharge outlets/air intakes. A special kit is available on request for connecting the boiler to a “coaxial 60/100PP” system, to be installed as shown in figure 28, where the vertical discharge is shown on the left under letter “A”...
5 - INSTALLATION 5.17.5 - “Coaxial 60/100 PP” system: available accessories The following accessories are available, on request, for installing the flue gas discharge/air intake system 60/100: (the number after the code refers to the part in the following drawings) 62617255 - No.
5 - INSTALLATION 5.17.6 - “Coaxial 60/100PP” system: installation examples When a coaxial discharge is installed (see figure 31), whether it is vertical or horizontal, it is indispensable to slope the discharge pipe upwards so as to get the condensation to flow inside the boiler. figure 31 - Installation examples for the coaxial pipe...
6 - OPERATING 6.1 - Operating from the central opening (flue remove the tube previously gas discharge), slowly pour in connected and check that there are Before starting the appliance up, it is approximately 100 cm3 (a glass full) no water leakages.
6 - OPERATING 6.3 - Gas type the minimum running temperature the table in section 9 at the end of (see section 7.4). the manual. indicated for the If the pump indicator is illuminated but the pump (see figure 1 detail “39”) is If the supply pressure does not fall within boiler not running, try releasing it using the...
6 - OPERATING 6.7 - Checking the comburant air pressure Since the boiler has a factory-set air/ gas ratio, the pressure of the gas at the burner is controlled indirectly; the comburant air pressure is checked inside the boiler and must correspond with that shown in the table in section 9 under the item “Comburant air pressure”...
6 - OPERATING 6.8 - Checking press the button to return and adjusting CO2 the boiler to normal operating conditions. levels The levels of CO2 (carbon dioxide) CAUTION!!! During this phase, in the boiler, under normal operating if the power supplied to the boiler is conditions, and below an altitude of much higher than the power absorbed 1,000m, are given in the table in section...
6 - OPERATING 6.9 - Adjusting the heating capacity The boiler has been constructed with an “intelligent” conception of the adjust- ment of the output heating, in relation to the effective requirement of the system, therefore it does not need adjusting. However, during the bringing onto stream BOILER MODEL of the system, the boiler runs for a brief...
7 - USE 7.1 - Adjusting the 7.3 - Thermostatic 7 . 4 . 1 - C l i m a t i c domestic hot water adjustment adjustment: on which The adjustment of the domestic hot water At the factory, the boiler is set with the systems? temperature (when present) is carried parameter at 00, or rather the...
7 - USE 7 . 4 . 2 - C l i m a t i c full running conditions and in its response requirements, just use control “31” as to the external temperature changes. A per figure 1, in order to raise or lower a d j u s t m e n t : high “Reaction”...
Page 36
7 - USE OA = Inclination of the line Ob = Minimum heating temperature Oc = Maximum heating temperature br = “fix point” of the angle External temperature (°C) fulcrum of the line b = parallel shift of the line (possible using the command on the panel) External temperature (°C) figure 38 -...
7 - USE 7.5 - Boiler settings (SwITChES) With just one control board (detail “13” of figure 1) it is possible to set the appliance in various different architectures. For this purpose, within the control board a series of electrical switches (see figure 21, detail “A”) is envisaged, identified by the wording SWITCHES, whose positioning (ON or OFF) determines the type of functioning of the appliance.
7 - USO 7 . 1 1 “ U s e r s ’ Press in order to confirm the menu” amended data and pass onto the next parameter. When entering the “Users’ menu”, the Once you have reached the end of the display “48”...
7 - USO 7.12 - “Installers’ menu” CAUTION!!! Changing these parameters could cause the boiler and therefore the system to malfunction. for this reason, only a technician who is sensitive to and has in-depth knowledge of the appliance can change them. The boiler’s micro-processor makes this menu of parameters available to the technician for the analysis of...
Page 40
7 - USE PARAMETER DESCRIPTION INfORMATION ON DISPLAy “48” Of fIGURE 1 Value in °C (cannot be changed) Boiler and heating supply tempe- rature, gauged by NTC1 sensor Domestic hot water tempera- Value in °C (cannot be changed) ture, gauged by NTC2 sensor Domestic cold water (or storage Value in °C (cannot be changed) tank) temperature, gauged by...
7 - USE 7.13 - Diagnostics During the routine functioning of the appliance, the display “48” as per figure 1, continually shows the operating status of the appliance, via the following indications: PARAMETER DESCRIPTION RIGhT-hAND DISPLAy Boiler temperature (°C) Boiler in stand-by mode or pause (no request for heating or domestic hot water) Boiler temperature (°C) Anti-freeze function active...
7 - USE 7.13.1 - Diagnostics: “L” lock-outs “L” Solutions Lock-out description Controls Code No flame detected after three Check: Gas supply pressure If the supply pressure is incorrect, it is subsequent ignition attempts (see section 6.6), sparks necessary to take steps upstream from the on ignitions electrodes (see appliance in order to restore it;...
Page 43
7 - USE Controls Solutions “L” Code Lock-out description Temperature difference Check that the electrical If one of the two or both sensors do not have between NTC1 and NTC6 element of the two sensors the correct values, it is necessary to replace complies with the graph in them;...
Page 44
7 - USE “E” Lock-out Controls Solutions Code description N T C 1 b o i l e r t e m p e r a t u r e Check that the electrical element If the electrical element of the probe does not sensor circuit short-circuited.
8 - MAINTENANCE 8.1 - General 8.2 - Disassembling warnings t h e c a s i n g a n d accessing internal CAUTION!!! Maintenance components operations must only be carried In order to disassemble the casing, out on the boiler by qualified proceed as follows (refer to figure 32): technicians.
8 - MAINTENANCE 8.3 - Cleaning of the condensation collecting trap In order to correctly clean the conveying and collection trap for the condensation produced by combustion, it is necessary to proceed as follows (refer to figures 42 and 43): ...
8 - MAINTENANCE 8.4 - Cleaning the burner and primary heat exchanger (flue gas side) To correctly clean the burner and the heat ex- changer (flue gas side), proceed as follows: access the internal components following instructions in section 8.2; ...
8 - MAINTENANCE 8.7 - Replacement of the pump motor If it becomes necessary to replace the circulator pump, proceed as follows (refer to figure 49): empty the water from the heating circuit, following the procedure indicated in section 8.10; ...
8 - MAINTENANCE 8.9 - Dismantling the 3-way valve The 3-way valve (detail “F” of figure 52) inverts the flow of water produced by the primary heat exchanger, to the heating circuit or the secondary heat exchanger for the production of d.h.w.. Should it become necessary to replace it, proceed as follows (refer to figures 51, 52 and 53):...
8 - MAINTENANCE 8.11 - Draining the 8.15 - Minimum and 8.10 - Draining the domestic side of the maximum output heating side of the It is possible to force the functioning appliance appliance of the appliance to its minimum or To empty the boiler from the domestic To empty the boiler from the heating maximum output, both during the heating...
8 - MAINTENANCE 8.17 - water temperature gauging sensor A number of sensors, which gauge the temperature, are positioned on the boiler’s heat exchanger. The electrical resistance existing between the two contacts of the sensor must correspond with the values shown in figure 55.
8 - MAINTENANCE 8.19 - functional wiring diagram - Command and control board C R - R e m o t e c o n t r o l (optional) C R04 - R emote control (optional) EA - Ignition electrode ER - Detector electrode F1 - Power supply fuse 1.6A F2 - Storage tank pump fuse...
10 - EC COMPLIANCE DECLARATION The undersigned company COSMOGAS S.r.L., with registered offices in Via L. Da Vinci 16 - 47014 Meldola (FC) ITALY, DECLARES under its own exclusive liability that the product: wARRANTy No GAS BOILER MODEL MANUfACTURE DATE...
Page 56
COSMOGAS s.r.l. Via L. da Vinci 16 - 47014 MELDOLA (FC) ITALY info@cosmogas.com www.cosmogas.com...