4.4.3
Keyboard Control Board
1. Refer to next figure.
2. Unscrew two screws[1]
3. Unplug connector [2] and remove the board.
When defective, replace the whole unit
Figure 4-18 Keyboard control board
4.4.4
IR/LED Board and Speakers
1. Refer to next figure.
2. Remove the screws [1] and remove the IR/LED board.
3. Remove the screws [2] and remove the speakers.
When defective, replace the whole unit.
2
1
1
Figure 4-19 IR/LED Board and Speakers
1
2
1
I_17930_063.eps
2
2
2
I_17930_043.eps
Mechanical Instructions
4.4.5
Power Supply Board
Due to different set executions this chassis is supplied with one
or two power supply boards and figures may differ.
Caution: it is absolutely mandatory to remount all different
screws and cables at their original position during re-assembly.
Failure to do so may result in damaging the power supply.
1. Refer to next figure.
2. Unplug all the connectors [1].
3. Remove the fixation screws [2]
4. Remove the main power supply board.
5. Unplug all the connectors [3].
6. Remove the fixation screws [4]
7. Remove the stand-by power supply board.
2
240408
2
240408
Q522.2E LA
1
2
4
3
1
2
Figure 4-20 Power Supply Unit(s)
4.
EN 15
3
4
4
4
I_17930_045.eps
240408