Cd Section - Sony CFD-E75 Service Manual

Hide thumbs Also See for CFD-E75:
Table of Contents

Advertisement

CFD-E75

CD SECTION

CD section adjustments are done automatically in this set.
In case of operation check, confirm that focus bias.
Focus Bias Check
1. Connect the oscilloscope to TP (RF) and TP (GND) on the CD
board.
2. Insert the disc (YEDS-18). (Part No. : 3-702-101-01)
[
]
u
3. Press the
(CD) button.
4. Confirm that the oscilloscope waveform is as shown in the
figure below. (eye pattern)
A good eye pattern means that the diamond shape (◊) in the
center of the waveform can be clearly distinguished.
• RF signal reference waveform (eye pattern)
VOLT/DIV: 0.2 V (with the 10: 1 probe in use.)
TIME/DIV: 500 ns
When observing the eye pattern, set the oscilloscope
for AC range and raise vertical sensitivity.
Adjustment Location:
– CD BOARD (Conductor Side) –
IC701
TP (GND)
18
0.85 ± 0.2 Vp-p
TP
(RF)