I Sequence Setup (Spot Monitor) - Panasonic WJ-HD500B Operating Instructions Manual

Digital disk recorder
Table of Contents

Advertisement

G Group Multi Sequence Setting
As described before, the cameras are assigned to 4
groups for recording with a programmed internal timer.
This item lets you select the sequence pattern to be dis-
played of each group on the Multiscreen Monitor.
G Group Multi Sequence Pattern Setting
1. Move the cursor to the GROUP SEQ MODE parameter
in the SEQUENCE SETUP by pressing the D or C but-
ton.
2. Select either QUAD or MULTI GROUP display mode to
be run on the monitor by pressing the + or - button.
MULTI GROUP: Camera images are displayed in
sequence with the minimum quantities of the seg-
ment screen.
QUAD: Camera images are displayed with a 4-segment
screen in sequence.
The factory default setting is QUAD.
G Dwell Time Setting
1. Move the cursor to the SEQ DWELL parameter in the
SEQUENCE SETUP by pressing the D or C button.
2. Select the desired dwell time for the group sequence
by pressing the + or - button.
1S - 30S: Selects the dwell time between 1 second and
30 seconds.
The factory default setting is 2S.
G Auto Skip Setting
This item lets you enable or disable the auto skip function
on the Multiscreen Monitor to skip any steps when no video
signal is present.
1. Move the cursor to the AUTO SKIP parameter in the
SEQUENCE SETUP by pressing the D or C button.
2. Select either ON or OFF by pressing the + or - but-
ton.
ON: Enables the auto skip function on the Multiscreen
Monitor.
OFF: Disables the auto skip function on the Multiscreen
Monitor.
The factory default setting is ON.

I Sequence Setup (Spot Monitor)

This item lets you program the live sequence pattern to be
run on the Spot Monitor.
Live sequence is a series of 16 steps assigned to the Spot
Monitor. This sequence can be run on the Multiscreen
Monitor by operating the buttons.
G Live Sequence Pattern Setting
1. Move the cursor to SPOT LIVE SEQUENCE SETUP in
the SEQUENCE SETUP menu by pressing the D or C
button, then press the SET button.
The menu shown below appears on the monitor screen.
5-1-3 SPOT LIVE SEQUENCE SETUP
PRE-
STEP CAM
SET
SEC
1
1
--
2S
2
2
--
2S
3
3
--
2S
4
4
--
2S
5
5
--
2S
6
6
--
2S
7
7
--
2S
8
8
--
2S
2. Move the cursor to the step editing area by pressing
the A, B, D or C button.
3. Select a camera number to be displayed for the CAM
editing area by pressing the + or - button.
1 - 16: Displays the image of the selected camera num-
ber.
--: Disables the display and will skip automatically.
4. Move the cursor to the PRESET editing area by press-
ing the B button, then select a preset position to be
displayed by pressing the + or - button, if applica-
ble.
1 - 64: Selects a preset position of the assigned cam-
era.
--: No preset position
The factory default setting is --.
Note: To assign the parameters 1 - 64, the specified
combination cameras are equipped in the system
with a PS
Data* mode.
5. Move the cursor to SEC editing area by pressing the B
button, then select the desired dwell time by pressing
the + or - button.
0S: The step will not be displayed on the monitor.
1S - 30S: Selects the dwell time between 1 second and
30 seconds.
The factory default setting is 2S.
PRE-
STEP CAM
SET
SEC
9
9
--
2S
10
10
--
2S
11
11
--
2S
12
12
--
2S
13
13
--
2S
14
14
--
2S
15
15
--
2S
16
16
--
2S
59

Advertisement

Table of Contents
loading

Table of Contents