CHAPTER 3. REPAIR INSTRUCTION
(1)-2
Mold part
2.8 FLASH UNIT
(1) FLASH UNIT
1. Remove the HIGH VOLTAGE CAUTION TAPE.
2. Remove the mold part of the FLASH UNIT from the dowel with the sharp point tweezers or the like.
3. Remove the two screws. (One screw from the front and the other from the rear.)
4. Remove the FLASH UNIT by sliding it.
5. Remove the EMS SHEET 1.
6. Remove the M-S FPC.
(1)-6
FLASH UNIT
c
(1)-3
Fig. 3-10 FLASH UNIT
3-10
M-S FPC
(1)-5
EMS SHEET 1
c
(1)-3
(1)-4