Quick Reference Guide for Viper FCB and FUB Units
Electrical Requirements:
Wiring:
Minimum Clearance Requirements:
Water Requirements:
CO
Requirements (2 regulators):
2
Syrup Tubing Requirements:
Before attempting to install or service this machine,
Page 1
Viper FCB/FUB Quick Reference Guide
read this Quick Reference Guide!
For more detail, refer to manuals supplied with the unit.
For Technical Service: 1-800-238-3600 (US); www.cornelius.com (Global)
215-245 VAC, 60 Hz supply voltage
2-Barrel: NEMAL6-20P Dedicated 20 Amp Circuit Required
3-Barrel: NEMA L6-30P Dedicated 30 Amp Circuit Required
4-Barrel: NEMA L6-30P Dedicated 30 Amp Circuit Required
NOTE: If voltage is less than 215 VAC or more than 245 VAC, then a Buck/Boost
transformer must be installed
All connections and wiring must comply with state and local codes.
Condenser air discharge is from the top of the unit. A minimum of 18 inches
clearance is required.
Cold air intake clearance is 2 inches on the sides of the unit or 2 inches in back.
25 psig flowing through 1/2" i.d. water supply line.
2 and 3-Barrels: At a volume of 100 GPH.
4-Barrel: At a volume of 150 GPH.
NOTE: If water requirements are less than minimum, then a water booster must
be installed. If water pressure is greater than 100 psig static, then a water regula-
tor must be installed
1 dedicated regulator set to 75 psig for pump supply located within six feet of
machine.
1 dedicated regulator set to 70 psig for FUB or 75 psig for FCB.
Most syrups use 3/8" inside diameter tubing up to 75 feet. 1/2" inside diameter
tubing is required for greater distances.
For FUB units, the length of tubing runs must not exceed 100 ft. horizontally and 10
ft. of vertical lift.
NOTE: High viscosity syrups require 1/2" inside diameter tubing for all distances.
June 8, 2012
620055004QRG
Rev. A

Advertisement

loading

Summary of Contents for Cornelius viper fcb

  • Page 1 Quick Reference Guide for Viper FCB and FUB Units 620055004QRG Viper FCB/FUB Quick Reference Guide Electrical Requirements: 215-245 VAC, 60 Hz supply voltage 2-Barrel: NEMAL6-20P Dedicated 20 Amp Circuit Required 3-Barrel: NEMA L6-30P Dedicated 30 Amp Circuit Required 4-Barrel: NEMA L6-30P Dedicated 30 Amp Circuit Required...
  • Page 2 Quick Reference Guide for Viper FCB and FUB Units 620055004QRG Plug the unit into the wall outlet and wait for initialization of the electronics and sold out alarms (there will be an audible beeping and display of the LCD screen).
  • Page 3 Quick Reference Guide for Viper FCB and FUB Units 620055004QRG Startup and Priming the System with Water, Syrup & CO (FCB units only) ALWAYS TURN ON WATER BEFORE CO Turn water supply on, then turn CO supply on (set to 75 psi...
  • Page 4 Quick Reference Guide for Viper FCB and FUB Units 620055004QRG Filling the Barrel/Motor Calibration/Freeze down Select BARREL MAINT and press GO. (See Figure 5b.) SELECT BARREL MAINT MANUAL DIAG TOTALS BRIX SETUP MOTOR SETUP 12:51P SYSTEM JUL 11 BACK MAIN SETUP...

This manual is also suitable for:

Viper fub