Quick Reference Guide for Viper FCB and FUB Units
Startup and Priming the System with Water, Syrup & CO
ALWAYS TURN ON WATER BEFORE CO
Turn water supply on, then turn CO
for Viper) and slowly turn the CO
75 psi for FCB or 70 psi for FUB), confirm CO
tanks is set to 30 psi (See Figure 1).
Turn three way valve to the BRIX position (See Figure 2) and
remove plug from end of sample tube (clear tygon tubing).
Place a flat blade screwdriver into the solenoid cover slots (as
shown in Figure 3) and manually purge water and syrup sys-
tems into a bucket until all air has been evacuated.
Go to the MAIN menu and select the Maintenance menu and then select BRIX Setup.
Place sample tube into cup and press GO. Cup will fill with a 3 second pour. Cycle three times and check the BRIX on the fourth pour with a refractometer (it should mea-
sure 13 BRIX). Pour a fifth drink to verify the reading. Adjust the syrup solenoid valve if BRIX is off-NEVER ADJUST THE WATER SOLENOID. When the process is com-
plete, lift the water solenoid to clean the sample tube, then turn the three way valve to the BARREL position and plug the line.
Repeat for all barrels.