Configuring BFD for RIP (single-hop detection in BFD echo
packet mode)
Network requirements
In the following figure, Switch A and Switch C are interconnected through a Layer 2 switch.
VLAN-interface 100 of the two switches runs RIP process 1, BFD is enabled on VLAN-interface 100 of
Switch A.
Switch A is connected to Switch C through Switch B. VLAN-interface 200 on Switch A runs RIP process
2; VLAN-interface 300 on Switch C, and VLAN-interface 200 and VLAN-interface 300 on Switch B run
RIP process 1.
Configure a static route and enable static route redistribution into RIP on Switch C. Switch A learns the
static route sent by Switch C, the outbound interface of the route is the interface connected to the Layer
2 switch.
Configure BFD so that when the link between Switch C and the Layer 2 switch fails, BFD can quickly
detect the link failure and notify it to RIP, and the BFD session goes down. In response, RIP deletes the
neighbor relationship with Switch C and the route information received from Switch C. Then, Switch A
learns the static route sent by Switch C with the outbound interface being the interface connected to
Switch B.
Figure 15 Network diagram
Configuration procedure
Configure IP addresses for interfaces. (Details not shown)
1.
Configure RIP basic functions.
2.
# Configure Switch A.
[SwitchA] rip 1
[SwitchA-rip-1] network 192.168.1.0
[SwitchA-rip-1] quit
[SwitchA] interface vlan-interface 100
[SwitchA-Vlan-interface100] rip bfd enable
[SwitchA-Vlan-interface100] quit
[SwitchA] rip 2
[SwitchA-rip-2] network 192.168.2.0