Vent-a-Hood AH12 Installation Instructions Manual

Vent-a-Hood AH12 Installation Instructions Manual

Wall mount hood

Advertisement

Quick Links

Read and Save These Instructions
All Hoods Must Be Installed By A Qualified Installer

INSTALLATION INSTRUCTIONS

AH12 WALL MOUNT HOOD
Read All Instructions Thoroughly Before Beginning Installation
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK,
OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
A. Installation work and electrical wiring must be done by qualified person(s)
in accordance with all applicable codes and standards, including fire-
rated construction. Switch power off at service panel and lock the service
disconnecting means to prevent power from being switched on accidentally
during installation.
B. When cutting or drilling into wall or ceiling, do not damage electrical wiring
and other hidden utilities.
C. Ducted fans must always be vented to the outdoors.
D. Sufficient air is needed for proper combustion and exhausting of gases
through the flue (chimney) of fuel burning equipment to prevent back
drafting. Follow the heating equipment manufacturer's guideline and
safety standards such as those published by the National Fire Protection
Association (NFPA), and the American Society for Heating, Refrigeration
and Air Conditioning Engineers (ASHRAE), and local code authorities.
E. ASHRAE residential ventilation standard 62.2 limits exhaust fans (total) to
a maximum of 15 CFM per 100 square feet of occupiable space, unless a
back drafting test is performed or make-up air is provided. Consult a local
HVAC engineer for make-up air evaluation.
WARNING - TO REDUCE THE RISK OF FIRE, USE ONLY METAL
L124 0516A
DUCTWORK
Page 1
U L
C
US
R

Advertisement

loading
Need help?

Need help?

Do you have a question about the AH12 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Vent-a-Hood AH12

  • Page 1: Installation Instructions

    Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: A.
  • Page 2 20 feet, increase the duct diameter by one inch for every ten feet of duct. A 90 degree elbow is equal to 5 feet of duct. Using Vent-A-Hood roof jacks or wall louvers (back page) will ensure proper efficiency. Airflow must not be restricted at the end of the duct run. Do not use screen wire or spring-loaded doors on wall louvers or roof jacks.
  • Page 3: Installation Details

    Installation Details 1) Read all instructions thoroughly before beginning installation. 2) When installing an AH12 wall mount hood, it is recommended that the bottom edge of the hood be located no more than 33” above the cooking surface for optimum performance.
  • Page 4 Installation Details Continued Connection Diagram (30” - 48”Widths) Blower Exhaust 1 ¾” 1 ⁄ ” Outlet 6" Round Wall Side Vent 2" Hole Electrical 12" 5 ¼” 6" Outlet Centerline Of Hood 300 CFM B100 Single Blower (Front View) (Top View) Connection Diagram (36”...
  • Page 5 Installation Details Continued Warning: Make sure power is off and locked at the service disconnecting means on the service panel during installation. 8) Install an appropriate 1/2” UL listed electrical wire clamp through the motor box electrical opening on top of the hood. Install electrical wiring from the service panel to the hood location for the motor box.
  • Page 6 VENTING ACCESSORIES WALL LOUVER WALL LOUVER WALL LOUVER RECTANGULAR WALL LOUVER 8 ⁄ ” 13” 11” 8 ½” 10” Back Back Back 6” 11” View View View 3 ¼” 7” 13” 6” 8” 1 ½” Flange 1 ½” Flange 1 ½” Flange MODEL MODEL MODEL...