1.3.6 OVERCRANK SHUTDOWN

After a prespecified duration of cranking, this func-
tion ends the cranking if the engine has failed to
start.

1.3.7 RPM SENSOR LOSS SHUTDOWN

If the speed signal to the control panel is lost, engine
shutdown will occur.
1.4
DC FUSES
These fuses are located inside the control panel. They
protect the panel wiring and components from dam-
aging overload. The unit will not start or crank if a
fuse is blown. Replace the fuses with the same size,
type, and rating.
1.5

FUEL SYSTEM

1.5.1 FUEL REQUIREMENTS

It is the responsibility of the installer to make sure
that only the correct recommended fuel is sup-
plied to the generator fuel system. Thereafter, the
owner/operator must make certain that only the
proper fuel is supplied.
For further information on the various types of
fuel systems, refer to Engine-Generator Standby
Electric Power Systems Installer's Guide and
Reference Manual (part #046622).

1.5.2 DIESEL FUEL SYSTEM

Diesel fuel is supplied to the generator set from a
base-mounted fuel tank.
Diesel fuels are less volatile than gaseous fuels, how-
ever, careless installation can lead to safety hazards
and/or serious problems with engine/generator per-
formance and reliability.
Appropriate care should be taken in applications
where extremely low ambient temperatures are
possible to ensure the temperature of the diesel
fuel is not allowed to fall below levels where "gell-
ing" could occur.
NOTE:
NOTE:
Section 1 – General Information
Standby Generator Set
1.6

SPECIFICATIONS

1.6.1 GENERATOR

Refer to the data label on the generator for rated
watts, amperes, frequency, voltage, phase and other
pertinent information.

1.6.2 ENGINE

General:
Cylinders and Arrangement ....................................................... 5 in-line
Displacement .................................................................. 3.0 L (186 in
Bore ............................................................................... 86 mm (3.4 in.)
Stroke .......................................................................... 105 mm (4.1 in.)
Compression Ratio .................................................................. 18.0-to-1
Number of Main Bearings ....................................................................5
Connecting Rods ...................................................... Drop Forged Steel
Aspiration .......................................................Turbocharged/Aftercooled
Governed Engine Speed ........................................................ 1800 rpm
Type of Valve Lifters .......................................................................Solid
Cylinder Head .......................................................................... Cast Iron
Pistons ........................................................................... Aluminum Alloy
Crankshaft ......................................................................... Forged Steel
Number of Flywheel Teeth ................................................................127
Engine Lubrication System:
Type of Oil Pump ................................................................ Gear Driven
Oil Filter .................................................................. Full Flow, Cartridge
Crankcase Oil Capacity ..................................... 11 L (11.7 U.S. quarts)
Fuel System:
Type of Fuel ................................................#2D Fuel (Min Cetane #40)
Consumption:*
Rated
25%
Freq.
Load
60 Hertz
1.2
*Given in: gal/h
Cooling System:
Type ....................................................... Pressurized, Closed Recovery
Coolant Capacity
System ................................................................17 L (4.5 U.S. gals.)
Engine ............................................................10.4 L (2.75 U.S. gals.)
Coolant Flow Per Minute .......................................106 L (28 U.S. gals.)
Heat Rejection to Coolant ............................................... 120,500 Btu/h
Cooling Fan (No. Blades) .....................................................................6
Diameter of Fan ............................................................ 560 mm (22 in.)
Cooling Airflow Required ........................................................6,800 cfm
Recommended Coolant .......................................See "Coolant" Section
Combustion Airflow Required ....................................................208 cfm
Exhaust System:
Exhaust Flow at Rated Output ..................................................533 cfm
Exhaust Outlet Size ...................................................................... 2.5 in.
Exhaust Temperature at Rated Output ......................... (518° C) 964° F
50%
75%
100%
Load
Load
Load
2.7
3.9
5.2
3
)