Problem and alarm code
The appliance does not fill with water.
The programme display shows E1.
An intermittent acoustic signal sounds
for approximately 30 seconds.
The anti-flood device is on.
The programme display shows E4.
An intermittent acoustic signal sounds
for approximately 30 seconds.
You cannot activate the appliance.
The programme does not start.
The appliance does not drain the water.
Once you have checked the appliance, set and
start the programme again. If the problem occurs
again, contact an Authorised Service Centre.
For alarm codes not described in the table, contact
an Authorised Service Centre.
12
Possible solution
Make sure that the water tap is open.
Make sure that the pressure of the water supply is
not too low. For this information, contact your local
water authority.
Make sure that the water tap is not clogged.
Close the water tap and contact an Authorised
Service Centre.
Make sure that the mains plug is connected to the
mains socket.
Make sure that there is no damaged fuse in the fuse
box.
Make sure that the appliance door is closed.
Press the start button.
If the delay start is set, cancel the setting or wait for
the end of the countdown.
Make sure that the drain hose is correctly connec-
ted.
Make sure that the filters in the appliance are clean.
Make sure that the kitchen sink drains correctly.
The necessary information for the Service Centre is
on the rating plate. record this information:
Model ......................
Serial number (SN.) ......................