4.0
Specification
4.1
Parameters
Interface
RS-422 connector
Transmission mode
4.2
Optical parameters
Wavelength
Optic fibre
Connectors
Fibre optic cable
Maximum data rate
4.3
Other
Supply
Dimension: Length
Width
Height
Weight
Stocking temperature
Working temperature
Humidity
5.0
Testing
When the power supply is connected the
appropriate LED has to be alight. To work
properly at least one of 8V or 6V LED must be
alight.
The LED diodes respective to the optic
transmitter/receiver
must blink during transmission.
820mm, multimode fibre
2x 50/125 or 62.5/125
ST
two single mode fibres 9/125 µm
115 200 bps
ext. DC supply of 6V/200mA galv. isolation
DC supply of 8V/170 mA (from DTE)
80mm
55mm
20mm
80g
-10° to +55°C
+0° to +50°C
0 – 85% (non-condensing)
(TRANSMIT/RECEIVE)
RS-422
DB9F
full duplex
5
ELOE174ZKE002