Elo TouchSystems ELO E00X Operation Manual

Rs-232 miniature converter to current loop

Advertisement

Quick Links

RS-232 Miniature Converter to Current Loop
ELO E00X
Operation manual

Advertisement

Table of Contents
loading

Summary of Contents for Elo TouchSystems ELO E00X

  • Page 1 RS-232 Miniature Converter to Current Loop ELO E00X Operation manual...
  • Page 2: Table Of Contents

    ELOE00XZKE001 Introduction ................3 Use of the converter ..............3 Operation principles ..............3 Installation ................3 RS-232 interface connection ........... 3 Two Modems interconnection ..........4 Power Supply Connection ............5 Specifications ................5 Parameters ................5 Other..................6 Testing ..................
  • Page 3: Introduction

    ELOE00XZKE001 Introduction RS-232 is the interface with asymmetric signals. Maximum load capacity can be 2500pF and equates to c.50m typical twisted-pair cable. The asymmetric signals are not ideal to eliminate the influence of zero potential differences of terminal equipments (TE and/or DTE). The TE and neutral potentials have to be the same hence the RS-232 interface is intended to the point-to-point connection for 15m distance.
  • Page 4: Two Modems Interconnection

    ELOE00XZKE001 abbrev trans.direction Signal name DB9 Female converter (DCE) Signal Ground Transmitted Data output input Received Data input output Request To Send output input Clear To Send input output Data Set Ready input output Data Terminal Ready output input Data Carrier Detect input output Two Modems interconnection...
  • Page 5: Power Supply Connection

    ELOE00XZKE001 Power Supply Connection The converter contains two isolated parts that have to be supplied from two supplies isolated from each other. The RS-232 interface circuit is supplied from the TE signals. The TE has to supply at least one of TxD, RTS and DTR signals. The power take-off does not exceed c.3mA.
  • Page 6: Other

    ELOE00XZKE001 Stocking temoerature - 10 to +55 Working temperature to +50 Humidity 0 – 85% (non-condensing) Other !!! Caution !!! The converter use is not allowed in lines exposed to the atmospheric electricity effects. Testing If interconnected properly, both diodes light up on each modem. Any simple communication test can be used (terminal emulator, …).
  • Page 7: Troubleshooting

    Check the power supply. Check RS-232 connection. Connection in normal Check the power supply. operation quit working Check the cable connection. Use auto-test and find out if the converter is OK. Ordering Information Supply code is ELO E00X.
  • Page 8 ELOE00XZKE001...