System Unit
Dimensions (H x W)
Media
Ports
System Inlet Temperature
Relative Humidity
(non-condensing)
Altitude
Power Consumption
Environment-
End-of-life Management and
friendly Products
Recycling
and Approach
HP QMH2572 8Gb FC HBA for HP BladeSystem c-Class
3.5 in x 3.9 in
N/A (Always connects to BladeSystem interconnect module)
Two
Operating
Non-operating
Operating
Non-operating
Operating
Non-operating
Max
Typical
Hewlett-Packard offers end-of-life HP product return, trade-in, and
recycling programs in many geographic areas. For trade-in information,
please go to: http://www.hp.com/go/green. To recycle your product, please
go to:
http://www.hp.com/go/green
Products returned to HP will be recycled, recovered or disposed of in a
responsible manner.
The EU WEEE directive (2002/95/EC) requires manufacturers to provide
treatment information for each product type for use by treatment facilities.
This information (product disassembly instructions) is posted on the Hewlett
Packard web site at: http://www.hp.com/go/green. These instructions may
be used by recyclers and other WEEE treatment facilities as well as HP OEM
customers who integrate and re-sell HP equipment.
c04126040 — DA – 14230 Worldwide — Version 6 — July 17, 2015
10° to 70°C (55° to 158°F) at sea level with an
altitude derating of 1.0°C per every 305 m (1.8°F
per every 1000 ft) above sea level to a maximum
of 3050 m (10,000 ft), no direct sustained
sunlight. Maximum rate of change is 10°C/hr
(18°F/hr). The upper limit may be limited by the
type and number of options installed.
System performance may be reduced if operating
with a fan fault or above 30°C (86°F).
-30° to 60°C (-22° to 140°F). Maximum rate of
change is 20°C/hr (36°F/hr).
10 to 90% relative humidity (Rh), 28°C (82.4°F)
maximum wet bulb temperature, non-
condensing.
5 to 95% relative humidity (Rh), 38.7°C (101.7°F)
maximum wet bulb temperature, non-
condensing.
3050 m (10,000 ft). This value may be limited by
the type and number of options installed.
Maximum allowable altitude change rate is 457
m/min (1500 ft/min).
9144 m (30,000 ft). Maximum allowable altitude
change rate is 457 m/min (1500 ft/min).
7.56 W
4.13 W on x8 PCIe Gen 1
3.8 W possible on x4 PCIe Gen 2 with PCIe Gen 2
capable system
or contact your nearest HP sales office.