Casing Removal - IDEAL Response SE Installation & Service Manual

Wall mounted, gas fired, fanned flue combination boiler
Hide thumbs Also See for Response SE:
Table of Contents

Advertisement

52 SAFETY
IMPORTANT.
Always turn OFF the gas supply at the gas service cock, and
switch OFF and disconnect the electricity supply to the
appliances before servicing.
WARNING.
After completing the servicing or exchange of components
always:
Test for gas soundness and carry out functional checks
as appropriate.
Check the sealing panel is correctly refitted, ensuring
that a good seal is made.

53 CASING REMOVAL

1.
Undo the securing screw.
2.
Lift to disengage the casing from the back panel and
withdraw it from the boiler.
38
SERVICING
Do NOT OPERATE the boiler if the
sealing panel is not fitted
Note.
In order to carry out servicing, the boiler casing and
sealing panel must be removed . Refer to Frames 53
and 54.
54 BOILER SEALING PANEL REMOVAL
1.
Release the 2 retaining clips.
2.
Swing the panel open to the left and disengage it from
the boiler.
Response SE Combi -
Installation