  • Page 1 Operation anual Digital P Combination System P C-5000 /5600...
  • Page 2 Welcome personal welcome to you from the management and employees of Inter-M ll of the co-workers here at Inter-M are dedicated to providing excellent products with inherently good value, and we are delighted you have purchased one of our products.
  • Page 3: Table Of Contents

    DIGIT L P COMBIN TION SYSTEM Contents Contents Unpacking ............................2 Installation Environment............................2 Important Safety Instructions......................2 Features ............................3 Front Panel ............................5 Rear Panel ............................9 Operating Method ........................17 1. Before Using the System......................17 2. System Operation........................17 3. FM Tuner Operations.........................18 4. MEDI (CD/USB/DRP) Operation ....................19 5.
  • Page 4: Unpacking

    DIGIT L P COMBIN TION SYSTEM Unpacking Unpacking lthough your P C-5000 /5600 is neither complicated nor difficult to operate, we recommend you take a few minutes to read this brief manual and familiarize yourself with the important information regarding product features, setup and operation.
  • Page 5: Features

    DIGIT L P COMBIN TION SYSTEM Features Features - BUDGET ND SP CE S VING INST LL TION The System incorporates most of the current P functions plus Emergency and normal broadcasting abilities thus allowing budget and space saving installation. - DU L BRO DC STING SYSTEM With two-channel (300W+300W) high power amplifier built-in, dual broadcasting is possible in 24 Zones separated by /B channels.
  • Page 6 DIGIT L P COMBIN TION SYSTEM - EMERGENCY POWER ND B TTERY CH RGING System has battery charge connect terminal for battery charge to provide emergency power. - FIRE DETECTION ND EMERGENCY BRO DC STING The system provides 24 channel sensor input terminals for automatic fire alarm broadcasting. It also provides the recording function of personalized alarm message.
  • Page 7: Front Panel

    DIGIT L P COMBIN TION SYSTEM Front Panel Front Panel 1. POWER SWITCH Switch turns the unit On or Off. 2. GROUP SELECT BUTTON (GROUP – , GROUP – B) Group /B speaker zone select/deselect button. 3. NOR / EM BUTTON Normal or Emergency select button.
  • Page 8 DIGIT L P COMBIN TION SYSTEM 8. EMERGENCY BRO DC ST TEST BUTTON (EM TEST) Test button to confirm the broadcast sound in the event of fire. In EM (Emergency) mode press and hold the button down to broadcast stored source and press down again to cancel the playback. You can also select separate speaker ZONE at this time.
  • Page 9 DIGIT L P COMBIN TION SYSTEM 20. MEDI FUN. BUTTON MEDI (CD/USB/DRP) select button. Each time the button is pressed, changes in the order of CD → USB → DRP. - CD Mode: CD Play - USB Mode: Play files stored in USB - DRP Mode: Play files stored in the internal memory 21.
  • Page 10 DIGIT L P COMBIN TION SYSTEM 31. NUMBER BUTTONS (0~9) Number buttons are used to enter numbers to search for tracks and to enter radio frequencies. 32. SYSTEM OPER TION INDIC TOR Displays the system operations such as Emergency Broadcast (EM), Fire (FIRE), reserved broadcast (PC), remote microphone broadcast (RM) and general broadcast (BGM).
  • Page 11: Rear Panel

    DIGIT L P COMBIN TION SYSTEM Rear Panel Rear Panel -P C-5000 11 12 13 20 22 24 23 25 26 : YH09015-15001 / MSIP-REM-IMK-PAC-5000A PAC-5000A SD CARD A SD CARD B MAIN POWER 100-240V~ 50/60Hz FAULT OUT REMOTE MIC (RM-6024)
  • Page 12 DIGIT L P COMBIN TION SYSTEM 2. DC POWER INPUT ND B TTERY CH RGE TERMIN L The emergency power supply and battery charging port can connect DC 24V battery. - Priority is given to C power when both C and DC power are both input. DC power is activated when C is cut off.
  • Page 13 DIGIT L P COMBIN TION SYSTEM 5. EXT CHIME/ FIRE COM EXT CHIME: Terminal to operate the CHIME2 using an external contact. FIRE COM: FIRE SENSOR common ground input terminal. 6. 24V – /24V – B TERMIN L Terminal used when 4-wire ttenuator is used. SPE KER OUTPUT terminals (+, –) and 24V – (or 24V – B), are used to connect COM port.
  • Page 14 DIGIT L P COMBIN TION SYSTEM HIGH IMPED NCE Speaker Installation ※ ZONE OUTPUT 1~24 ZONE (Caution when connecting). Group , B, respectively (12 ZONE) the sum of power output is not over (300W + 300W). 11. M IN POWER SWITCH (M IN POWER) The switch is used to turn On and Off the C power.
  • Page 15 DIGIT L P COMBIN TION SYSTEM - P C-5000 : RS-232C Terminal RS-232 SERI L terminal for remote control access. Remote control is possible with the PC program provided separately. Purpose Receive Transmit Ground ※For how to use the remote control, please refer to the SOFTW RE M NU L. 15.
  • Page 16 DIGIT L P COMBIN TION SYSTEM Fire contact Macro functions can be set with web (P C-5600) or PC program (P C-5000 ). For detailed instructions please refer to the SOFTW RE M NU L. ※Note: When input comes in during standby mode, emergency broadcast system turns on and broadcasts to pre-selected ZONE speakers.
  • Page 17 - System set to SL VE is displayed as “SL VE (1~4)” in the front display window. - The system set to SL VE cannot use its own sources. : YH09015-15001 / MSIP-REM-IMK-PAC-5000A PAC-5000A SD CARD A...
  • Page 18 DIGIT L P COMBIN TION SYSTEM 24. UX1 INPUT J CKS ND CONT CTS bility to use UX1 as BGM input from an external source input. Priority is same as BGM. - COM Contact Input, group’s BGM will be selected to UX1. B - COM Contact Input, B group’s BGM will be selected to UX1.
  • Page 19: Operating Method

    DIGIT L P COMBIN TION SYSTEM Operating Method Operating Method 1. Before using the system 1) Set all the volumes to minimum level before connecting to a wall outlet. 2) Please make sure that the speaker and the input terminals are connected properly. In particular, make sure that the MP input / output jacks on the rear panel are connected properly.
  • Page 20: Fm Tuner Operations

    3) System Remote Control Method Please refer to the SOFTW RE M NU L. ※PC Program, Software M NU L can be downloaded from (www.inter-m.com). 3. FM TUNER Operation 1) How to uto/Manual tune radio frequencies - Use either Group or B input button to light the LED on TUNER.
  • Page 21: Medi (Cd/Usb/Drp) Operation

    DIGIT L P COMBIN TION SYSTEM 4) FM MUTE Function No display of TUNED indicates no broadcast or weak/noisy signals. Pressing FM MUTE button will display “ UTO” and bypass all weak or noisy stations. ➡ When the normal broadcast signal is received TUNED is displayed and the broadcast is automatically resumed.
  • Page 22 DIGIT L P COMBIN TION SYSTEM - USB • Plays the files stored in a USB memory device. • Press MEDI FUN button to select USB mode. ➡ • When the USB device is inserted in the USB reader, reads the information and goes to standby mode displaying TOT L number of files available.
  • Page 23 DIGIT L P COMBIN TION SYSTEM 5) COPY Function bility of copying CD and USB source materials to the DRP(Internal Memory). - CD COPY • bility to copy the contents of the CD to the DRP. CD playback and COPY is done at the same time. •...
  • Page 24 DIGIT L P COMBIN TION SYSTEM 6) DELETE (File Delete) Function Function to delete unnecessary files from the DRP (internal memory). - Folder Delete • Press MEDI button to select DPR. • Pressing DELETE button will change to delete mode and “FOLDER1” is displayed. •...
  • Page 25: Dd-On Operation Methods

    DIGIT L P COMBIN TION SYSTEM 5. dd-on Operation Methods 1) System Version Display Function Display the system version. - Press INFO button and press I◀◀ / ▶▶I button to verify “VER. #.#.#.#”. 2) System IP information display (P C-5600 Only) Display units’...
  • Page 26 DIGIT L P COMBIN TION SYSTEM 5) SPE KER LINE CHECK Function (P C-5600 Only) Function to check if the speaker line is connected properly. - CONFIRM: Test to store the current speaker line connect state. • Press INFO button and press I◀◀ / ▶▶I button to select “SPE KER CONFIRM”. •...
  • Page 27 DIGIT L P COMBIN TION SYSTEM 6) Battery Check Function (P C-5600 Only) Check the currently connected emergency battery’s condition. - CONFRIM: To check and store the battery condition as a reference. • Push INFO button and push I◀◀ / ▶▶I button to select “B TTERY CONFIRM”. •...
  • Page 28 DIGIT L P COMBIN TION SYSTEM Display Condition GOOD The Best Condition. NOT B D Periodic CHECK is necessary. Replace the battery. 7) System Initialization (P C-5600 Only) Reset the IP address and web page settings. - IP default value: 192.168.1.99 - For web page settings, reservation broadcast, please refer to the SOFTW RE M NU L for more details.
  • Page 29: Connections

    DIGIT L P COMBIN TION SYSTEM Connections Connections CD-6208 CD-6208 PAC-5600 (MASTER) PAC-5600 (SLAVE) RM-6024 RS-232 (PAC-5000A) NETWORK (PAC-5600) : YH09015-15001 / MSIP-REM-IMK-PAC-5000A PAC-5000A SD CARD A SD CARD B MAIN POWER 100-240V~ 50/60Hz FAULT OUT REMOTE MIC (RM-6024) LINK NETWORK...
  • Page 30: Block Diagram

    DIGIT L P COMBIN TION SYSTEM Block Diagram Block Diagram - P C-5000 P C-5000 /5600...
  • Page 31 DIGIT L P COMBIN TION SYSTEM Block Diagram Block Diagram - P C-5600 P C-5000 /5600...
  • Page 32: Specifications

    DIGIT L P COMBIN TION SYSTEM Specifications Specifications P C-5000 P C-5600 UX INPUT ( UX IN @ 1kHz, 100V/33.33 , 70V/16.6 LO D OUTPUT) Rated Output (@ T.H.D 1%, GROUP + GROUP B) 300W+300W Input Sensitivity -10 ± 3dBV Signal-to-Noise Ratio (S/N) >75dB EQ Control (100Hz, 1kHz, 10kHz)
  • Page 33 DIGIT L P COMBIN TION SYSTEM P C-5000 P C-5600 Operating Temperature -10°C ~ +40°C Power Source C 100–240V, 50/60Hz, DC 24V Power Consumption (1/8W) 135W Weight (SET) 11.1kg/24.4lb 11.2kg/24.7lb Dimension (SET) 482(W)×177(H)×373(D)mm/19(W)x 7(H) x 14.7(D) in * Design and specification are subject to be changed for the improvement of product quality without pre notice. P C-5000 /5600...
  • Page 34 DIGIT L P COMBIN TION SYSTEM ※ DIMENSIONS P C-5000 /5600...
  • Page 35: Service

    To obtain specific warranty information and available service locations contact Inter-M directly or the authorized Inter-M Distributor for your specific country or region.
  • Page 36 Inter-M, Ltd. (Korea) began operations in 1983. Since then, Inter-M has grown to become one of the largest manufacturers of professional audio and commercial sound electronics equipment in the world. Inter-M has gained worldwide recognition for its own branded products, as well as private label manufacturing of electronics sold under other names (OEM).