5. TECHNICAL DATA AND CHARACTERISTICS
43
126
5
16
56
278
20
21
22
42
10
8
44
fig. 19 - General view
7
6
3
5
2
4
3
1
2
1
0
0
500
fig. 20 - Circulating pumps Head/Pressure losses Prodotto_25
A = Boiler pressure losses - 1, 2 and 3 = Circulating pump speed
Important: Before connecting the room thermostat or the remote timer con-
A
trol, remove the jumper on the terminal block.
8
EN
7
9
38
11
1.000
1.500
Q [l/h]
cod. 3540S920 - 05/2009 (Rev. 00)
Supplied By www.heating spares.co Tel. 0161 620 6677
DOMIcondens F 28
Data
Max. heating capacity
Min. heating capacity
277
Max. Heat Output in heating (80/60°C)
Min. Heat Output in heating (80/60°C)
Max. Heat Output in heating (50/30°C)
Min. Heat Output in heating (50/30°C)
Max. heating capacity in hot water production
Min. heating capacity in hot water production
Max. Heat Output in hot water production
Min. Heat Output in hot water production
27
Gas supply pressure G20
19
Max. gas delivery G20
Min. gas delivery G20
26
Gas supply pressure G31
Max. gas delivery G31
Min. gas delivery G31
81
Efficiency class Directive 92/42 EEC
NOx emission class
186
Max. working pressure in heating
Min. working pressure in heating
193
Max. heating temperature
Heating water content
14
Heating expansion tank capacity
Heating expansion tank prefilling pressure
36
Max. working pressure in hot water production
Min. working pressure in hot water production
114
DHW flowrate Dt 25°C
DHW flowrate Dt 30°C
Protection rating
32
Power supply voltage
Electrical power input
Electrical power input in hot water production
Empty weight
Type of unit
PIN CE
Key of figures cap. 5
5
Sealed chamber
7
Gas inlet
8
Domestic hot water outlet
9
Cold water inlet
10
System delivery
11
System return
A
14
Safety valve
16
Fan
19
Combustion chamber
20
Burner assembly
21
Main nozzle
22
Burner
26
Combustion chamber insulation
27
Copper exchanger for heating and hot water
32
Heating circulating pump
36
Automatic air vent
38
Flow switch
2.000
42
DHW temperature sensor
43
Air pressure switch
44
Gas valve
47
Modureg
56
Expansion tank
72
Room thermostat
81
Ignition and detection electrode
114
Water pressure switch
126
Contact fume thermostat
139
Remote timer control
186
Return sensor
193
Trap
277
Condensing recuperator
278
Double sensor (Safety + Heating)
Unit
DOMIcondens F 28
kW
27.2
kW
10.0
kW
26.2
kW
9.2
kW
28.2
kW
9.6
kW
27.2
kW
10.0
kW
26.5
kW
9.2
mbar
20
3
2.88
m
/h
3
1.06
m
/h
mbar
37
kg/h
2.13
kg/h
0.78
-
-
3
bar
3
bar
0.8
°C
90
litres
1.5
litres
8
bar
1
bar
9
bar
0.25
l/min
15.2
l/min
12.7
IP
X5D
V/Hz
230V/50Hz
W
135
W
135
kg
35
C13-C23-C33-C43-C53-C63-C83-B23-B33
0063BR3161
(Q)
(Q)
(P)
(P)
(NOx)
(PMS)
(tmax)
(PMW)
(D)