Deluxe 7 channel platinum remote start system with keyless entry (12 pages)
Summary of Contents for Audiovox AA-925
Page 1
Model AA-925 Installation Manual Keyless Entry System With Two Auxiliary Outputs Installation Instructions This Unit Is Intended For Installation In Vehicles With 12 Volt Negative Ground Electrical Systems Only. Kit Contents: (1) Control Module (2) - Three Button Transmitters 4 Channel Code Learning Receiver On Board Antenna (1) - Multi Pin Input/Output Harness (1) - Three Pin Door Lock Harness...
The AA-925 Keyless Entry System is designed to provide a convenient electronic means to gain access to the vehicle by providing RF remote control over the vehicle's power door lock system. The unit also includes outputs to control the vehicle's dome lights, as well as exterior parking lights. Although not an alarm system, this unit also incudes a starter interrupt circuit output.
Page 3
NOTE: Some vehicles, (mostly European) have isolated "left" and "right" side parking lights. To connect to the parking light systems in these vehicles, you must use separate SPDT relays to connect to each side in order to keep them isolated. Attach the WHITE wire of the system to this point. BROWN Wire: Negative (-) Door Sense Input Wire If the vehicle's interior lights are controlled by grounding door pin switches (typical of most GM, Chrysler, and import vehicles), the Brown negative door sense wire should connect to one of the vehicle's factory door pin switches.
Page 4
GREEN/BLACK Wire: Immediate, 300mA Duration of Transmit, Channel 3 Output The Green/Black wire supplies a 300mA switched output whenever Channel 3 of the receiver is accessed. Pressing A combination of the transmitter Lock/UnLock buttons simultaneously will access Channel 3 and will remain active for as long as the transmitter button(s) is held.
Page 5
The green wire provides a positive pulse during locking, or the pulsed + 12 volt lock output. Connect the green wire to the wire that provides a low current positive signal from the factory door lock switch to the factory door lock control relay. 3 Wire Positive Switched 2 Step Door Locks The green wire provides a positive pulse during locking, or the pulsed + 12 volt lock output.
Page 6
Programmable Features: Features 1 Chirp First Passive Arming Active Arming Second Ignition D/L ON Ignition D/L OFF Third Ignition D/UL ON Ignition D/UL OFF Fourth Chirps ON Chirps OFF Fifth Passive D/L Active D/L Sixth Siren Output Horn Output Seventh 800ms D/L Pulse 3.5 Sec.
Fourth Turn the valet switch on then off Press transmitter Lock button to change Fifth Turn the valet switch on then off Press transmitter Lock button to change Sixth Turn the valet switch on then off Press transmitter Lock button to change Seventh Turn the valet switch on then off Press transmitter Lock button to change Press transmitter lock button to change...