Gas Connections; Check For Leaks - GE JGRP20 Installation Instruction

24-inch gas
Hide thumbs Also See for JGRP20:
Table of Contents

Advertisement

Available languages

Available languages

Installation
Instructions
GAS CONNECTIONS
(cont.)
Ill
Place the oven in the cutout.
r_
Level the oven:
1. Place a spirit level on one of the oven
racks.
2. If the oven is not level, adjust the leg
levelers.
3. Remove
regulator
cover at the back of
the storage drawer area by removing
4 screws.
With the oven in place, the pressure
regulator
inlet is accessible
through
the
opening
in the main back.
_]
Through
this opening
connect:
1. The flexible
connection
and the adaptor
(see Fig. 7).
or
2. The rigid pipe connection
and union to the
shutoff
valve (see Fig. 8).
Pressure Regulator
Adantor
with Built-In
\
_"
Shut-Off
r ° __
Va,ve
II
FLEXIBLEHOOK-UP
Pressure Regulator
Union
Flexible
Connection
Regulator
Cover
Fig. 7
"_
Regulator
t_
Cover
Fig. 8
RIGID HOOK-UP
_-_
-Iqghten the fitting.
WARNING:
DO NOT FORCE!
FORCING COULD DAMAGE THE FITTING,
TUBING OR CAUSE LEAKING.
CHECK FOR LEAKS
44,WARNING:
DO NOT USE OPEN
FLAME TO CHECK FOR LEAKS!
r_
Apply a soap solution
to all connections:
supply line, manifold
and oven.
_']
Turn on the main gas supply.
_']
Check for any bubbles to form.
[_]
Turn off main gas supply.
[_]
Stop any leaks found.
[_]
Turn main gas supply on to make sure all
leaks were stopped.
r-G-] Replace the regulator
cover using the 4
screws previously
removed.
WARNING:
ALL LEAKS MUST BE
STOPPED BEFORE ATTEMPTING
TO LIGHT
BURNERS.
PRESSURE TEST INFORMATION
The maximum
allowable
pressure for the
regulator
is 14" W.C.
The minimum
pressure
needed to check the
regulator
setting
is 11" W.C. for L.P. gas and
5" W.C. for Natural.
CAUTION:
The range and
its individual
shutoff
valve must be
disconnected from the gas supply piping
system during any pressure testing of the
gas supply system at test pressures in
excess of 1/2 psig (pound per square inch
gauge).
The range must be isolated from the gas supply
piping system
by closing its individual
manual
shut-off
valve during
any pressure testing
of the
gas supply system at test pressures
equal to or
less than 1/2 psig.
5