Hydraulic Preformance Curve
Hydraulic Performance Table
P(psi)
H (ft)
80
180
70
160
60
140
120
50
100
40
80
30
60
150 (.5 HP)
20
40
10
20
0
0
0
5
10
15
Suction Lift Performance Table
Capacity in US Gallons per Minute
Discharge
RGW
Pressure
Model
in PSI
0
10
16.6
15.6
150
20
12
11
30
7.1
5.8
10
22.5
22.1
20
20.7
20.2
250
350
30
18.3
17.8
450
40
14.7
13.8
50
10.5
9.3
Pump Specification Table
Power
Cycle
RGW Model
(H.P.)
(Hz)
150
.5
60
250/350/450
1
60
Capacity And Power Consumption Table
Capacity
RGW
Model
Liters Gallons
A
150
150
40
45.5
250
250
66
60
350
350
93
53
450
450
119
60
13.0 Technical Data
RGW Series
.5 - 1 H P
60 Hz
250/350/450 (1 HP)
20
30
40
50
60
70 US GPM
Suction Lift in Feet
5
10
15
20
25
14.6
13.6
12.7
11.7
10
9
7.8
6.6
4.5
3.2
2
0.6
21.7
21.3
20.8
20.5
19.8
19.2
18.8
18.2
17.1
16.2
15.3
14.2
12.9
12.1
11.1
10.2
8.1
6.9
5.6
4.3
Phase
Voltage
Amps
(Ф)
(V)
(A)
1
115/230
6/3
1
115/230
11/5.5
Dimensions
(Inch)
B
C
D
E
38.25
25
22.5
22.75
52.5
39.5
22.5
22.75
45.5
33
22.5
30.5
52.5
39.5
22.5
30.5
UG_RGW_v1.12_EN
Grey In
Grey Out
Fresh In
Over ow
B
Max Pump
Boost
Pressure
40
67
Pre-Set
H Max
Q Max
(PSI)
(ft)
(GPM)
24
92
18.5
28
154
23.8
Estimated Annual Consumption
Weight
Max
in Kw/h (by number of people)
People
Kg
lbs
2
41
90
2
41
43
95
4
69
47.5
105
6
69
50
110
8
69
D
Made In Canada
C
E
Power
(H.P.)
4
6
8
69
97
126
.5
125
182
239
1
125
182
239
1
125
182
239
1
Page 15
A
Service
Drain
Start-up
IAPMO
(watts)
Aproved
2100
Yes
2800
Yes
2800
Yes
2800
Yes