IF REQUIRED BY LOCAL CODES.
CROSS CONNECTION
CONTROL DEVICE
BYPASS
VALVE
POTABLE
WATER MAIN
SHUT-OFF
VALVE
GREY WATER
OUT SHUT-OFF
VALVE
The backwater valve device prevents contamination in the event of a sewage back up.
The cross connection control device prevents contamination of the potable water system
The freshwater bypass valve provides water to toilets incase of power failure or maintenance.
The grey water bypass prevents fixture drains from backing up incase of a filter obstruction.
The vent and overflow pipes must be at least the same size as the inlet pipe (maximum 3")
If an optional pre-filter is employed on the grey water in line, an additional overflow between the
pre-filter and grey water in tank connection must be installed.
The grey water bypass must be lower than any fixture suppling grey water to the RGW system to
prevent fixture backup.

9.0 System Connections

PRIMING/
IRRIGATION
FAUCET
GREY WATER
OUT TO
TOILETS
POTABLE
WATER IN
Figure 5. RGW System Connections
UG_RGW_v1.12_EN
GREY WATER PIPE FROM
TUBS & SHOWERS
WYE FITTING
DRAIN VALVE
VENT PIPE TO
OUTSIDE
WYE FITTING
GREY WATER
BYPASS
6"
GREY WATER
BYPASS VALVE
P-TRAP
OVERFLOW PIPE
TO BUILDING
DRAIN
BACK WATER
VALVE
Page 11