Panasonic BT-LH900A Operating Instructions Manual page 24

Lcd video monitor
Hide thumbs Also See for BT-LH900A:
Table of Contents

Advertisement

REMOTE specifications
RS-232C connector
For the RS-232C connector pin layout and connections, refer
to the figure below and tables on the right.
<Note>
The RS-232C remote control specifications of this BT-
LH900A are not compatible with those of the conventional
BT-LH900.
If you wish to remotely control the BT-LH900A by using the
same remote control specifications as those of the BT-
LH900, then contact your dealer.
5
9
PC side
Pin No.
Signal
1
N.C.
2
RXD
3
TXD
4
DTR
5
GND
6
DSR
7
RTS
8
CTS
9
N.C.
24
(continued)
RS-232C
4
3
2
1
8
7
6
BT-LH900A side
Pin No.
Signal
1
N.C.
2
TXD
3
RXD
4
DSR
5
GND
6
DTR
7
CTS
8
RTS
9
N.C.
RS-232C REMOTE operation
method
$ Connectors and signal names
Connector: D-SUB 9-pin (female)
Pin No.
Signal name
1
N.C.
Not connected
2
TXD
Transmission data
3
RXD
Reception data
4
DSR
Connected inside.
5
GND
Ground
6
DTR
Connected inside.
7
CTS
Connected inside.
8
RTS
Connected inside.
9
N.C.
Not connected
$ Communication Conditions
Signal level
Conforms to RS-232C
Synchro system
Tone pace synchro system
Transfer rate
9600 bps
Parity
None
Data length
8 bit
Stop bit
1 bit
Flow control
None
$ Command format
STX (02h)
Command
OCommands are 3 characters following STX, finally
adding ETX.
OAdd a : (colon) after the command as required, and add
the data.
$ Response formats
1. Setting command response
STX (02h)
Command
2. Query command response
STX (02h)
Data
3. Error response
STX (02h)
Error code
Error code
ER001 : Invalid command
ER002 : Parameter error
Explanation
:
Data
ETX (03h)
ETX (03h)
ETX (03h)
ETX (03h)

Advertisement

Table of Contents
loading

Table of Contents