Coleman TH4B1821S Technical Manual page 51

Lx series split system 14 seer – r-410a – 1 phase 1.5 thru 5 nominal tons
Hide thumbs Also See for TH4B1821S:
Table of Contents

Advertisement

FURNACE MULTIPLIERS - 3 TON (Continued)
Furnaces
Coil
TMLX100C16MP11
CF/CM/CU36D
TMLX100C16MP11
CF/CM/CU42C
TMLX100C16MP11
CF/CM/CU42D
TMLX100C20MP11
CF/CM/CU36C
TMLX100C20MP11
CF/CM/CU36D
TMLX100C20MP11
CF/CM/CU42C
TMLX100C20MP11
CF/CM/CU42D
TMLX120C20MP11
CF/CM/CU36C
TMLX120C20MP11
CF/CM/CU36D
TMLX120C20MP11
CF/CM/CU42C
TMLX120C20MP11
CF/CM/CU42D
TP9C060B12MP11
CF42B
TP9C080B12MP11
CF42B
TP9C080C16MP11
CF/CM/CU42C
TP9C100C16MP11
CF/CM/CU42C
TP9C100C20MP11
CF/CM/CU36C
TP9C100C20MP11
CF/CM/CU42C
TP9C120D20MP11
CF/CM/CU42D
TPLC080B12MP11
CF42B
TPLC080C16MP11
CF/CM/CU36C
TPLC080C16MP11
CF/CM/CU42C
TPLC100C16MP11
CF/CM/CU36C
TPLC100C16MP11
CF/CM/CU42C
HEATING PERFORMANCE DATA
CONDENSING UNIT MODEL NO
AIR TEMP.
ENTERING
OUTDOOR UNIT (°F)
INDOOR COIL (°F)
60
47
40
30
17
10
NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT. KW VALUES ARE FOR THE SYSTEM (OUTDOOR + INDOOR).
Yellow shaded cells are AHRI High Heating conditions.
Orange shaded cells are AHRI Low Heating conditions.
Multipliers for determining the performance with other indoor sections.
Johnson Controls Unitary Products
T.C.
S.C.
1.03
1.05
1.03
1.08
1.04
1.08
1.02
1.04
1.03
1.05
1.04
1.08
1.04
1.10
1.02
1.04
1.03
1.05
1.04
1.08
1.04
1.10
1.02
1.05
1.02
1.05
1.02
1.06
1.02
1.06
1.02
1.04
1.02
1.06
1.03
1.08
1.02
1.06
1.02
1.04
1.04
1.10
1.02
1.04
1.04
1.10
TH4B3521S
AIR TEMP.
ENTERING
MBH
60
41.0
70
39.9
80
38.8
60
35.2
70
34.3
80
33.5
60
32.1
70
31.4
80
30.7
60
27.4
70
26.9
80
26.5
60
23.2
70
22.9
80
22.5
60
20.9
70
20.6
80
20.3
FURNACE MULTIPLIERS - 3 TON (Continued)
KW
Furnaces
0.95
TPLC100C20MP11
0.95
TPLC100C20MP11
0.96
TPLC120C20MP11
0.96
TPLC120C20MP11
0.94
CP9C060B12MP11
0.96
CP9C080B12MP11
0.94
CP9C080C16MP11
0.96
CP9C100C16MP11
0.94
CP9C100C20MP11
0.96
CP9C100C20MP11
0.94
CP9C120D20MP11
0.98
CPLC080B12MP11
0.98
CPLC080C16MP11
0.98
CPLC080C16MP11
0.98
CPLC100C16MP11
0.98
CPLC100C16MP11
0.98
CPLC100C20MP11
0.95
CPLC100C20MP11
0.98
CPLC120C20MP11
0.96
CPLC120C20MP11
0.97
0.96
0.97
1000
COP
KW
MBH
3.64
2.93
41.6
3.24
3.23
40.0
2.90
3.54
38.4
3.22
2.82
35.8
2.88
3.12
34.9
2.59
3.41
34.0
2.99
2.77
32.6
2.67
3.08
32.0
2.39
3.38
31.4
2.60
2.71
28.1
2.33
3.00
27.2
2.11
3.30
26.3
2.30
2.59
23.2
2.07
2.86
22.8
1.87
3.14
22.5
1.95
2.77
20.7
1.74
3.08
20.6
1.58
3.40
20.5
5005749-CTG-A-0216
Coil
T.C.
CF/CM/CU36C
1.02
CF/CM/CU42C
1.04
CF/CM/CU36C
1.02
CF/CM/CU42C
1.04
CF42B
1.02
CF42B
1.02
CF/CM/CU42C
1.02
CF/CM/CU42C
1.02
CF/CM/CU36C
1.02
CF/CM/CU42C
1.02
CF/CM/CU42D
1.03
CF42B
1.02
CF/CM/CU36C
1.02
CF/CM/CU42C
1.04
CF/CM/CU36C
1.02
CF/CM/CU42C
1.04
CF/CM/CU36C
1.02
CF/CM/CU42C
1.04
CF/CM/CU36C
1.02
CF/CM/CU42C
1.04
ID CFM
1200
COP
KW
MBH
3.67
2.87
42.2
3.25
3.15
40.1
2.89
3.44
38.0
3.25
2.78
36.4
2.91
3.07
35.5
2.63
3.35
34.6
3.00
2.74
33.1
2.69
3.04
32.6
2.43
3.33
32.0
2.62
2.69
28.7
2.33
2.97
27.5
2.09
3.25
26.2
2.22
2.60
23.1
2.02
2.87
22.8
1.84
3.13
22.6
1.89
2.75
20.43
1.71
3.06
20.5
1.56
3.38
20.6
S.C.
KW
1.04
0.98
1.10
0.97
1.04
0.98
1.10
0.97
1.05
0.98
1.05
0.98
1.06
0.98
1.06
0.98
1.04
0.98
1.06
0.98
1.08
0.95
1.06
0.98
1.04
0.96
1.10
0.97
1.04
0.96
1.10
0.97
1.04
0.98
1.10
0.97
1.04
0.98
1.10
0.97
1400
COP
KW
3.70
2.81
3.27
3.07
2.88
3.33
3.27
2.74
2.94
3.01
2.66
3.28
3.00
2.71
2.71
3.00
2.46
3.28
2.64
2.66
2.33
2.93
2.06
3.20
2.15
2.62
1.97
2.87
1.82
3.12
1.84
2.73
1.68
3.05
1.55
3.36
51

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents