Solutions for problems
If your air conditioner malfunctions, check the following information to find
solutions or probable causes of the failure. Do not try to repair the unit by
yourself, if these solutions do not solve the failures; call your local service
repair team.
Poor Equipment performance
1. The air outlet or inlet in the exterior part is obstructed.
2. The temperature in the exterior is high due to direct sunlight or another
heat source.
3. Heater or a cooking stove is being used in the same room.
4. Room is full of people.
5. The air filter is obstructed by dust or is dirty.
6. Inappropriate temperature adjustment.
7. Front part is obstructed.
8. The capacity of the equipment is not adequate for the size of the room.
9. Air conditioner was just turn on.
10.Windows or doors are open.
The unit does not start
1. The plug is not connected to the outlet.
2. No electricity in the outlet.
3. The voltage is different.
4. Temperature is not adjusted properly.
5. burned fuse.
6. The remote control batteries need to be replaced.
7. wrong operation time.
Attention
Stop the air conditioner immediately if one of the following
malfunctions occur
1. The operation indicator or other indicator flash(5 times per second) and the
flashing is not stop by disconnecting and connecting the unit.
2. Frequent change of fuses and malfunctions in the switch circuit.
3. Water spills over the equipment.
4. Remote control does not work.
5. Any other abnormal situation.

Solution for problems

49

Technical specifications

Cool models
WASC09C5CRKW
UNIDAD EXTERNA
WASE09C5CRKW
UNIDAD INTERNA
Cycle
Cool
Cooling power (Btu/h)
9000
Heating power (Btu/h)
-
Rated voltage (V)
220
Frequency (Hz)
50
Indoor unit width (mm)
790
Indoor unit high (mm)
275
Indoor unit depth (mm)
196
Indoor unit net weight (kg)
8
Outdoor unit width (mm)
700
Outdoor unit high (mm)
540
Outdoor unit depth (mm)
240
Outdoor unit net weight (kg)
23
Heat and Cool models
WASC09P5CRKW
UNIDAD EXTERNA
WASE09P5CRKW
UNIDAD INTERNA
Heat/Cool
Cycle
Cooling power (Btu/h)
9000
Heating power (Btu/h)
9000
Rated voltage (V)
220
Frequency (Hz)
50
Indoor unit width (mm)
710
Indoor unit high (mm)
250
Indoor unit depth (mm)
189
Indoor unit net weight (kg)
7
Outdoor unit width (mm)
685
Outdoor unit high (mm)
430
Outdoor unit depth (mm)
260
Outdoor unit net weight (kg)
21
WASC12C5CRKW
WASC18C5CRKW
WASC24C5CRKW
WASE12C5CRKW
WASE18C5CRKW
WASE24C5CRKW
Cool
Cool
Cool
12000
18000
24000
-
-
-
220
220
220
50
50
50
790
930
1036
275
275
315
196
198
230
8
11.5
15.5
700
780
845
540
540
695
240
250
335
27
34.5
42
WASC18P5CRKW
WASC24P5CRKW
WASC12P5CRKW
WASE18P5CRKW
WASE24P5CRKW
WASE12P5CRKW
Heat/Cool
Heat/Cool
Heat/Cool
12000
18000
24000
12000
18000
24000
220
220
220
50
50
50
790
930
1036
275
275
315
196
198
230
7,5
10
13
700
780
820
540
540
600
240
250
345
23,5
33
47