Refrigerant Piping Connection - White-Westinghouse WAS(C,E)09C5CRKW Instruction Manual

Table of Contents

Advertisement

Settlement of outdoor unit
Anchor the outdoor unit tightly and
horizontally on a concrete or rigid
mount with a bolt and nut 10 or 8
diameter.
MODEL
700x535x235
685x430x260
780x540x250
760x590x285
820x600x345
845x695x335
895x860x330
Drain joint installation
Fit the seal into the drain elbow, then
insert the drain joint into the base
pan hole of outdoor unit, rotate 90 to
securely assemble them. Connecting
the drain joint with an extension
drain hose (Locally purchased), in
case of the water draining off the
outdoor unit during the heating
mode.
+
=
Seal
Drain joint
Outdoor unit installation
17
A
Air inlet
Air
inlet
B
Air outlet
A (mm)
B (mm)
458
250
460
276
549
276
530
290
523
340
560
335
590
333
Base pan hole
of outdoor unit
Seal
Drain pipe

Refrigerant piping connection

Flaring work
Main cause for refrigerant leakage is
due to defect in the flaring work.
Carry out correct flaring work using the
following procedure:
1. Cut the pipes and the cable.
A) Use the piping kit accessory or
pipes purchased locally.
B) Measure the distance between the
indoor and the outdoor unit.
C) Cut the pipes a little longer than the
measured distance.
D) Cut the cable 1.5m longer than the
pipe length.
2. Burr removal
A) Completely remove all burrs from
the cut cross section of pipe/tube.
B) Put the end of the copper.
tube/pipe in a downward direction
as you remove burrs in order to
avoid dropping burrs into the
tubing.
3. Putting nut on.
A) Remove flare nuts attached to
indoor and outdoor unit, then put
them on pipe/tube having
completed burr removal.(not
possible to put them on after flaring
work)
Refrigerant piping connection
Pipe
Correct
Wrong
Oblique Roughness Burr
Pipe
Reamer
Point
down
Flare nut
Cooper tube
18