Appendix 4 - Default Settings; A4.1 Company Standard; A4.1.1 Common Configuration; A4.1.2 Process Groups 1 And 2 - ABB SM1000 User Manual

Videographic recorder
Hide thumbs Also See for SM1000:
Table of Contents

Advertisement

APPENDIX 4 – DEFAULT SETTINGS

A4.1 Company Standard

A4.1.1 Common Configuration

Setup
Configuration type
Number of groups
Time format
Date format
Language
Global alarm
acknowledge source
Instrument tag
Security
User names
User passwords
Configuration security type
Setup level security
Setup level password
Logs
Alarm log size
Totalizer log size
Audit log size
Operator messages (all)
Tag
Message source ID

A4.1.2 Process Groups 1 and 2

Recording
Group 1 tag
Group 2 tag
Recording enable source
Sample rate source
Primary sample rate
Secondary sample rate
Chart View
Chart view enable
Annotation
Screen interval
Major chart divisions
Minor chart divisions
Menu enables
Message select
Alarm acknowledge
Scale select
Trace select
Screen interval select
Historical review
Chart annotation select
Bargraph View
Bargraph view enable
Markers
Menu enables
Message select
Alarm acknowledge
Max./min. reset
•1 Applicable only to instruments fitted with the totalizer options.
Basic
1
hhmmss
ddmmyy
English
None
SM1000
Operator 1, 2 etc.
0
Password protected
Off
0
200
200
•1
200
""
None
Process group 1
Process group 2
None
None
10s
1s
On
Off
3 minutes
3
10
False
True
False
False
True
True
False
Off
No markers
False
True
False
...A4.1.2 Process Groups 1 and 2
Process View
Process view enable
View select
Menu enables
Message select
Alarm acknowledge
Totalizer reset
Totalizer stop/go
View select
Digital Indicator View
Digital indicator view enable
Menu enables
Message select
Alarm acknowledge
Archiving
Data file enable
Alarm event log file enable
Totalizer log file enable
Audit log file enable
New file generation interval
Auto update enable
Digital save source

A4.1.3 Recording Channels

Setup
Source indentifiers
Channels 1.1 to 1.6
Channels 2.1 to 2.6
Trace colors
Channels 1.1 and 2.1
Channels 1.2 and 2.2
Channels 1.3 and 2.3
Channels 1.4 and 2.4
Channels 1.5 and 2.5
Channels 1.6 and 2.6
Filter type (all channels)
Analog Inputs (A1 to A6 and B1 to B6)
Type
Electrical range (high)
Electrical range (low)
Engineering range (high)
Engineering range (low)
Filter time
Linearizer type
Fault detect level
Broken sensor drive
Engineering units
Mains frequency
Short tag
Long tag
Digital recording channels
Long tag
Short tag
On tag
Off tag
Off
Statistics
False
False
False
•1
False
•1
False
Off
False
True
False
False
False
•1
False
Off
False
None
Analog input A1 to A6
Analog input B1 to B6
Magenta
Red
Black
Green
Blue
Brown
Instantaneous
mA
20
4
100
0
0
Linear
10%
Downscale
%
50Hz
I/P xx
Analog input xx
Blank
Blank
On
Off
83

Advertisement

Table of Contents
loading

Table of Contents