electricity supply cable from the wall
must align with rear cable entry point
in the backplate.
4. Mark the location on the wall with a
pencil. Use the backplate to mark the
locations for the four fixing points.
5. Drill holes.
6. Fix the optional back panel if
required.
4
Connecting to terminal block.
6mm
L
L
N
N
Warning: Risk of electric shock!
Ensure power is not connected.
1. Ensure the cable does not sit above
the cable guide from the cable inlet
to the terminal block. If the cable
sits above the guide walls it may
interfere with main components,
prevent the security screws being
fitted correctly, or risk the main body
being forced on to the backplate,
causing damage.
2. Unscrew the cable clamp from
the backplate. Remove the cable
terminal block.
3. Open the flap on the terminal
block. Secure the live, neutral and
earth wires into the correct terminal
locations as indicated on the
terminal block casing.
6mm
4. Verify the connections are correct
before proceeding.
5. Close the flap on the terminal block
and fit it into the backplate.
6. Screw in and secure the cable clamp.
CAUTION: DO NOT OVERTIGHTEN
AND CRUSH THE POWER CABLE.
3.1
Rear cable entry.
6mm
● Primary fixing locations (x4).
Do not use countersunk screws.
Secondary fixing locations.
Fixing the backplate to the wall.
Fit the backplate securely to the wall
using the appropriate fixings for the
wall type and weight of the unit. Do
not use counter-sunk screws.
Do not secure tightly until after the
power cable has been secured.
Installing the power cable.
1. Cut the entry hole in the rubber
cable grommet to the correct size:
leave a hole smaller than the
diameter of the power cable to
ensure the cable fits tightly.
2. Pull the cable through the
grommet. Ensure the cable is long
enough to route correctly through
the backplate to the terminal
block.
5
Attaching main body.
CAUTION: Do not overtighten screws.
1. Hook the main body of the unit over
the top rim of the backplate.
2. Swing the main body of the unit
down on to the back plate. (For
installations with the cable entry on
the side, ensure that the side bracket
seal is correctly seated against the
main body.)
3. Insert and tighten the (2) security
screws into the side of the main body
with the service tool as illustrated.
Recommended torque of 0.5-
0.7NM.
4. Turn power on.
5. Test unit for correct operation.
15
The cable must sit in the
dedicated channel.
3. Fit the grommet into the
backplate. Ensure it is secure.
4. Secure the screws in the
backplate.
5. Proceed with step 4, 'Connecting
to terminal'.
IMPORTANT
DO NOT USE SEALANT WHEN
FIXING THE UNIT TO THE WALL.
DO NOT PAINT/COAT THE MAIN
BODY OR PLACE GRAPHICAL
STICKERS ON IT OR THIS MAY
DAMAGE THE ANTI-BACTERIAL
SURFACE.
IF A CLEANING PRODUCT IS LEFT
ON THE MACHINE FOR TOO LONG,
A FILM WILL FORM. THIS MAY
REDUCE THE EFFECTIVENESS OF THE
ANTI-BACTERIAL SURFACES.